Crit-Line Clip (Clic) Blood Chamber
Accessories, Blood Circuit, Hemodialysis. 510(k) K152953, from Fresenius Medical Care North America (Waltham, MA). Product code KOC, class 2.
As of Nov 20, 2026, K152953 is an FDA 510(k) held by Fresenius Medical Care North America, substantially equivalent on Nov 5, 2015 after 29 days, with no recalls tied to it in FDA's recall database.
- Review time: 29 days
- Recalls: 0
- Cited as a predicate by: 1 device
The CRIT-LINE Clip (CLiC) Blood Chamber is a sterile, single use, disposable, optical cuvette designed for use with the CLiC Monitor’s sensor clip during acute and chronic hemodialysis therapy to non-invasively measure hematocrit, percent change in blood volume, and oxygen saturation.
- Crit-Line Clip (Clic) Blood ChamberK141281 · Fresenius Medical Care Renal Therapies Group, LLC · Aug 14, 2014
- CombiSet SMARTECH Hemodialysis Blood Tubing Set with attached Priming Set and Integrated Crit-Line Technology, CombiSet…K201207 · Fresenius Medical Care Renal Therapies Group, LLC · Sep 18, 2020
- BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series (AL-ADC-E(U),…K242176 · Nikkiso Co., Ltd. · May 15, 2025
- BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR HEMODIALYSIS C18 Series AL-ADC-PU,…K242479 · Nikkiso Co., Ltd. · May 15, 2025
- Blood Tubing Lines for Hemodialysis AV06C-EK231589 · Nikkiso Co., Ltd. · Jul 28, 2023
- Blood Tubing Lines for Hemodialysis AL Series (Archloop), Blood Tubing Lines for Hemodialysis C18 SeriesK230514 · Nikkiso Co., Ltd. · Jun 16, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Oct 7, 2015
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5820
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files