Aequalis FX2
Shoulder Prosthesis, Reverse Configuration. 510(k) K141345, from Tornier S.A.S. (Montbonnot-Saint-Martin, FR). Product code PHX, class 2.
As of Nov 20, 2026, K141345 is an FDA 510(k) held by Tornier S.A.S., substantially equivalent on Nov 18, 2014 after 180 days, with 1 recall tied to it in FDA's recall database.
- Review time: 180 days
- Recalls: 1
- Cited as a predicate by: 1 device
IN ANATOMIC: The Aequalis Fx2 humeral stem combined with the Flex Shoulder System humeral head may be used by themselves, as a hemiarthroplasty, if the natural glenoid provides a sufficient bearing surface, or in conjunction with the glenoid, as a total replacement.
- Aequalis Ascend Flex Shoulder SystemK122698 · Tornier S.A.S. · Jan 8, 2013
- Aequalis Shoulder Fracture System & Aequalis Shoulder SystemK060209 · Tornier · Mar 2, 2006
- Aequalis Shoulder Fracture System, Aequalis Reversed Shoulder Prosthesis, Aequalis Reversed Fracture Shoulder ProthesisK131231 · Tornier S.A.S. · Oct 16, 2013
- Aequalis Reversed Fracture Shoulder ProthesisK082120 · Tornier · Oct 24, 2008
- Comprehensive Reverse Shoulder Humeral TrayK113069 · Biomet Manufacturing Corp · Jan 11, 2012
- Aequalis Fx2K152966 · Tornier S.A.S. · Jan 14, 2016
| Started | Recall | Status |
|---|---|---|
| Sep 19, 2016 | Z-0699-2017Tornier is conducting a recall on Aequalis Fx2 ( implant parts and instrument trays) due to reports of dislocations of the poly insert and the stem. | Terminated |
- Easytech Reversed Shoulder SystemK260417 · FX Shoulder Solutions, Inc. · Nov 5, 2026
- Veritas Shoulder SystemK263421 · restor3d, inc. · Oct 22, 2026
- AltiVate Reverse® Glenosphere with RAVN™ TechnologyK263086 · Encore Medical L.P. · Oct 2, 2026
- Veritas Shoulder SystemK260556 · Restor3D · Jul 1, 2026
- Augment Off-Axis Instrument SystemK261683 · Zimmer, Inc. · Jun 16, 2026
- Tornier Perform Reversed Glenoid and Tornier Perform Reversed Augmented Glenoid Shoulder SystemK260102 · Stryker Corporation (Tornier, Inc.) · Jun 12, 2026
- MSS - Humeral reverse liners extensionK261016 · Medacta International, SA · Jun 10, 2026
- Veritas Reverse Total Shoulder SystemK253992 · Restor3D · May 7, 2026
- Japan approved Aequalis Reversed Cementless, the same brandPMDA · Sep 14, 2015
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 22, 2014
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3660
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files