PHX: Shoulder Prosthesis, Reverse Configuration
FDA product code PHX. Class II, classified under 21 CFR 888.3660. What the classification flags say about Part 820 under the QMSR.
As of Nov 2, 2026, FDA product code PHX (Shoulder Prosthesis, Reverse Configuration) is Class II under 21 CFR 888.3660, reviewed through 510(k), with 207 linked 510(k), De Novo or BK numbers, 0 PMAs and 69 recall product records.
Classification
- Product code
- PHX
- Device name
- Shoulder Prosthesis, Reverse Configuration
- Device class
- Class II
- Regulation
- 21 CFR 888.3660
- Review panel
- Orthopedic
- Premarket route
- 510(k)
- CGMP-exempt flag
- No
- Life-sustaining flag
- No
- Implant flag
- Yes
- Third-party review
- Not a candidate
- Summary malfunction reporting
- Eligible
FDA definition. Intended to be used to relieve pain and to replace the glenoid and humeral side of the shoulder joint in order to restore mobility in a grossly rotator cuff deficient joint with severe arthropathy or a previous joint replacement with a grossly rotator cuff deficient joint.
Data from openFDA as of 2 November 2026. Read the record on openFDA · FDA product code classification database
Part 820 requirements the flags point to
Part 820 rules for PHX
- CGMP exemptionClassification regulation, 21 CFR parts 862 to 892
- Not flaggedFDA does not flag this product code as exempt.A manufacturer of a finished device of this type falls under part 820 (21 CFR 820.1(a)). Some classification regulations exempt only part of a generic device type, so read the regulation for your device.FDA: QMSR, CGMP exemptions · 21 CFR 820.35
- Design and development, ISO 13485 clause 7.321 CFR 820.10(c)
- Rule names this classRule names Class II.21 CFR 820.10(c) requires manufacturers of class II and class III devices to comply with clause 7.3 and its subclauses.21 CFR 820.10
- Traceability, ISO 13485 clause 7.5.9.221 CFR 820.10(d)
- Not flaggedFDA does not flag this code as life-supporting or life-sustaining.The code is flagged as an implant. 820.10(d) names devices that support or sustain life. The old rule, 820.65, also named devices intended for surgical implant. FDA said the scope of 820.10(d) is substantially similar to the old rule. The flag shows implant status. It does not decide whether 820.10(d) applies.21 CFR 820.10 · 21 CFR 860.3 · QMSR final rule, comment 49
- Complaint and record content21 CFR 820.35
- Rule names this classApplies to every finished-device manufacturer, exempt or not.820.35 adds content to complaint records, servicing records and UDI recording on top of ISO 13485 clause 4.2.5. FDA says CGMP exemption does not lift these records.21 CFR 820.35 · FDA: QMSR, CGMP exemptions
These flags describe the classification of a product code. They are not a determination for a specific device or manufacturer. How a manufacturer meets 21 CFR 820.10 depends on its own device, its intended use and the full text of the rule.
Clearances and recalls on record
- 510(k), De Novo and BK numbers linked
- 207 · Search these clearances
- PMA numbers linked
- 0
- Recall product records
- 69
- Adverse event reports
- Search MAUDE for PHX
Recall records count products, and one recall event can add many. Counts show activity in a category. They do not measure its safety.
Newest PHX clearances
- Veritas Shoulder System: restor3d, inc., Oct 22, 2026
- AltiVate Reverse® Glenosphere with RAVN™ Technology: Encore Medical L.P., Oct 2, 2026
- Veritas Shoulder System: Restor3D, Jul 1, 2026
- Augment Off-Axis Instrument System: Zimmer, Inc., Jun 16, 2026
- Tornier Perform Reversed Glenoid and Tornier Perform Reversed Augmented Glenoid…: Stryker Corporation (Tornier, Inc.), Jun 12, 2026
- MSS - Humeral reverse liners extension: Medacta International, SA, Jun 10, 2026
- Veritas Reverse Total Shoulder System: Restor3D, May 7, 2026
- Comprehensive Reverse Shoulder - HA Glenosphere Baseplates: Biomet Orthopedics, Apr 15, 2026
- Equinoxe® Shoulder System: Exactech, Inc., Apr 14, 2026
- InSet Reverse Total Shoulder System: Shoulder Innovations, Inc., Apr 13, 2026
Search all 7,098 product codes, or read the guide to the Part 820 rules behind these flags.
Check your quality documents against Part 820
Arca puts your SOPs and design files in a library and compares them against the Part 820 requirements for your device in a grid, one row per document and one column per requirement, with each cell cited to its source.