Aequalis Reversed Shoulder Prosthesis
Shoulder Prosthesis, Reverse Configuration. 510(k) K140478, from Tornier S.A.S. (Montbonnot-Saint-Martin, FR). Product code PHX, class 2.
As of Nov 18, 2026, K140478 is an FDA 510(k) held by Tornier S.A.S., substantially equivalent on Aug 6, 2014 after 161 days, with no recalls tied to it in FDA's recall database.
- Review time: 161 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFCemented Aequalis Reversed prosthesis: It is indicated for patients with a functional deltoid muscle as a total shoulder replacement for the relief of pain and significant disability following arthropathy associated with the massive and non repairable rotator cuff-tear. This device is also indicated for the prosthetic revisions with massive and non repairable rotator cuff-tear.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Aequalis Reversed Shoulder ProsthesisK030941 · Tornier · May 14, 2004
- Aequalis Reversed ProsthesisK061439 · Tornier · Jul 20, 2006
- Aequalis Reversed Shoulder ProsthesisK081059 · Tornier · Jul 17, 2008
- Aequalis Reversed Shoulder ProsthesisK100142 · Tornier · May 6, 2010
- Comprehensive Reverse Shoulder - Titanium GlenosphereK131353 · Biomet Manufacturing Corp · Oct 8, 2013
Cited as a predicate
2 later 510(k) summaries name this device as a predicate- Delta Xtend Reverse Shoulder SystemK183077 · Depuy(Ireland) · May 17, 2019
- Aequalis Ascend Flex Shoulder System, Aequalis Reversed Shoulder ProsthesisK151293 · Tornier S.A.S. · Sep 24, 2015
Other PHX clearances
The newest 510(k)s for the same product code; their median review was 132 days; see every PHX device- Easytech Reversed Shoulder SystemK260417 · FX Shoulder Solutions, Inc. · Nov 5, 2026
- Veritas Shoulder SystemK263421 · restor3d, inc. · Oct 22, 2026
- AltiVate Reverse® Glenosphere with RAVN™ TechnologyK263086 · Encore Medical L.P. · Oct 2, 2026
- Veritas Shoulder SystemK260556 · Restor3D · Jul 1, 2026
- Augment Off-Axis Instrument SystemK261683 · Zimmer, Inc. · Jun 16, 2026
- Tornier Perform Reversed Glenoid and Tornier Perform Reversed Augmented Glenoid Shoulder SystemK260102 · Stryker Corporation (Tornier, Inc.) · Jun 12, 2026
- MSS - Humeral reverse liners extensionK261016 · Medacta International, SA · Jun 10, 2026
- Veritas Reverse Total Shoulder SystemK253992 · Restor3D · May 7, 2026
Elsewhere
- Japan approved Aequalis Reversed Cementless, the same brandPMDA · Sep 14, 2015
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 26, 2014
- Review panel
- Orthopedic
- Regulation
- 21 CFR 888.3660
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files