Flow-I Anesthesia System C20, C30 & C40
Gas-Machine, Anesthesia. 510(k) K133958, from Maquet Critical Care AB (Wayne, NJ). Product code BSZ, class 2.
As of Nov 19, 2026, K133958 is an FDA 510(k) held by Maquet Critical Care AB, substantially equivalent on Mar 20, 2014 after 86 days, with 8 recalls tied to it in FDA's recall database.
- Review time: 86 days
- Recalls: 8
- Cited as a predicate by: 1 device
The indication for FLOW-i Anesthesia System is administering inhalation Anesthesia while controlling the entire ventilation of patients with no ability to breathe, as well as in supporting patients with a limited ability to breathe. The system is intended for use on neonatal to adult patient populations.
- Maquet Flow-I C20, Maquet Flow-I C30, Maquet Flow-I C40K112114 · Maquet Critical Care AB · Jan 13, 2012
- FLOW-i Anesthesia System C20, FLOW-i Anesthesia System C30, FLOW-i Anesthesia System C40K160665 · Maquet Critical Care AB · Mar 29, 2017
| Dec 11, 2023 | Z-0989-2024, Z-0988-2024, Z-0987-2024, Z-0991-2024, Z-0990-2024Potential cybersecurity vulnerability that could lead to a Denial of Service (DoS) attack, tampering, or remote code execution via remote login to the Flow Anesthesia System, any of which could lead to a hazardous… | Open |
| Dec 10, 2015 | Z-0804-2016Electrical issues in the control, monitoring or panel sub-systems, caused by the printed circuit boards (PCBs) that control the sub-systems. The problems manifested as multiple re-starts of the sub-systems and, in a few… | Terminated |
| Apr 2, 2015 | Z-1706-2015In some Flow-i Anesthesia Systems, patient cassette can get dislodged which could result in gas leakage within the system internal circuit potentially leading to a stop in ventilation. | Terminated |
| Mar 2, 2015 | Z-2083-2015Maquet has identified that in some FLOW-i Anesthesia System Auxiliary O2 and Suction Modules, the suctioning function cannot be activated or controlled by the suction unit on/off switch leading to a decrease or loss of… | Terminated |
- A5 Anesthesia System (A5); A7 Anesthesia System (A7)K253330 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Jun 25, 2026
- Atlan (A100); Atlan (A100 XL); Atlan(A350); Atlan (A350 XL)K252746 · Drägerwerk AG Co. Kgaa · May 21, 2026
- Codonics Safe Labeling System-Point of Care Station (PCS) (SLS-700i and related 610i, 620i, 630i series enabled to…K251352 · Codonics.Incorporated · Jul 11, 2025
- AtlanK230931 · Drägerwerk AG Co. Kgaa · Jul 23, 2023
- Carestation 750/750cK213867 · Datex-Ohmeda, Inc. · Mar 28, 2023
- A8, A9 Anesthesia SystemK201957 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Mar 26, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Abbreviated
- Received
- Dec 24, 2013
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5160
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files