Maquet Flow-I C20, Maquet Flow-I C30, Maquet Flow-I C40
Gas-Machine, Anesthesia. 510(k) K112114, from Maquet Critical Care AB (Wayne, NJ). Product code BSZ, class 2.
As of Nov 19, 2026, K112114 is an FDA 510(k) held by Maquet Critical Care AB, substantially equivalent on Jan 13, 2012 after 172 days, with 1 recall tied to it in FDA's recall database.
- Review time: 172 days
- Recalls: 1
- Cited as a predicate by: 1 device
The indication for FLOW-i Anaesthesia System is administering inhalation Anaesthesia while controlling the entire ventilation of patients with no ability to breathe, as well as in supporting patients with a limited ability to breathe. The system is intended for use on neonatal to adult patient populations.
- Maquet Flow-I C20, Maquet Flow-I C30, Model 66 77 200, 66 77 30K102182 · Maquet Critical Care AB · May 9, 2011
- GE Datex-Ohmeda AisysK090233 · Datex-Ohmeda, Inc. · Mar 5, 2009
- Flow-I Anesthesia System C20, C30 & C40K133958 · Maquet Critical Care AB · Mar 20, 2014
| Started | Recall | Status |
|---|---|---|
| Feb 20, 2012 | Z-1925-2012A technical alarm may be generated on the FLOW-i system when using the MAN/AUTO switch to change ventilation modes from manual to automatic or from automatic to manual if the switch is not fully engaged in the "on" or… | Terminated |
- A5 Anesthesia System (A5); A7 Anesthesia System (A7)K253330 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Jun 25, 2026
- Atlan (A100); Atlan (A100 XL); Atlan(A350); Atlan (A350 XL)K252746 · Drägerwerk AG Co. Kgaa · May 21, 2026
- Codonics Safe Labeling System-Point of Care Station (PCS) (SLS-700i and related 610i, 620i, 630i series enabled to…K251352 · Codonics.Incorporated · Jul 11, 2025
- AtlanK230931 · Drägerwerk AG Co. Kgaa · Jul 23, 2023
- Carestation 750/750cK213867 · Datex-Ohmeda, Inc. · Mar 28, 2023
- A8, A9 Anesthesia SystemK201957 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Mar 26, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jul 25, 2011
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5160
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files