Dimension Exl With Lm System
Analyzer, Chemistry (Photometric, Discrete), For Clinical Use. 510(k) K130276, from Siemens Healthcare Diagnostics, Inc. (Newark, DE). Product code JJE, class 1.
As of Nov 18, 2026, K130276 is an FDA 510(k) held by Siemens Healthcare Diagnostics, Inc., substantially equivalent on Mar 22, 2013 after 45 days, with 6 recalls tied to it in FDA's recall database.
- Substantially equivalent: Mar 22, 2013
- Review time: 45 days
- Recalls: 6
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Dimension® EXL™ with LM system is an in vitro diagnostic device that is intended to measure a variety of analytes in human body fluids. The system utilizes photometric, turbidimetric, chemiluminescence and integrated ion selective multisensor technology for chemical and immunochemical applications for clinical use.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Dimension Exl With Lm Clinical Chemistry System, Dimension FT4L Flex Reagent Cartridge, And Loci Thyroid Calibrator, ModK073604 · Dade Behring, Inc. · Mar 13, 2008
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Dimension Loci Free Thyroxine Flex Reagent Cartridge, FT4L, Dimension Loci Thyroid Stimulating Hormone Flex Reagent CartK140842 · Siemens Healthcare Diagnostics, Inc. · Nov 26, 2014
Recalls
Recalls FDA ties to K130276, newest first; each opens FDA's recall record| Sep 28, 2018 | Z-0409-2019Thermal chamber motors have electrical cables with single insulation rather than the required double insulation. There is no exposed current due to the single insulation that could result in a potential electrical shock | Terminated |
| Nov 10, 2015 | Z-0458-2016Siemens has identified RMS refrigeration compressors that are missing the safety cover on the electrical termination block. The exposed electrical hazard on the electrical termination block is located directly behind… | Terminated |
| Nov 10, 2015 | Z-0459-2016Siemens has identified RMS refrigeration compressors that are missing the safety cover on the electrical termination block. The exposed electrical hazard on the electrical termination block is located directly behind… | Terminated |
| Apr 2, 2015 | Z-1615-2015Certain Dimension Integrated Chemistry Systems Instrument Power Configurations may have been installed with a non-standard instrument power plug.The use of a non-standard plug configuration as described may lead to a… | Terminated |
| Jul 16, 2014 | Z-2553-2014The Reagent Lid hinge may lose its effectiveness and slowly shift downward during maintenance procedures, potentially resulting in physical contact and injury to the operator. | Terminated |
| May 27, 2014 | Z-2133-2014There is a misassembly issue with the photometer installed on Dimension Integrated Chemistry Systems instruments. Through internal investigation by Siemens Healthcare Diagnostics has confirmed that a limited number of… | Terminated |
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Feb 5, 2013
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.2160
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files