Dimension Exl With Lm Clinical Chemistry System, Dimension FT4L Flex Reagent Cartridge, And Loci Thyroid Calibrator, Mod
Radioimmunoassay, Free Thyroxine. 510(k) K073604, from Dade Behring, Inc. (Newark, DE). Product code CEC, class 2.
As of Nov 18, 2026, K073604 is an FDA 510(k) held by Dade Behring, Inc., substantially equivalent on Mar 13, 2008 after 83 days, with 7 recalls tied to it in FDA's recall database.
- Substantially equivalent: Mar 13, 2008
- Review time: 83 days
- Recalls: 7
- Cited as a predicate by: 4 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe FT4L method is an in vitro diagnostic test for the quantitative measurement of Free Thyroxine in human serum and plasma on the Dimension® EXL™ with LM system. Measurements of free thyroxine are used in the diagnosis and monitoring of thyroid disease. The LOCI® Thyroid Calibrator is an in vitro diagnostic product for the calibration of the FT4L method on the Dimension® EXL™ with LM system.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Dimension(R) Xl Clinical Chemistry SystemK944093 · E.I. Dupont DE Nemours & Co., Inc. · Nov 10, 1994
- Dimension Vista Free Thyroxine Flex Reagent Cartridge And Loci 1 CalibratorK053531 · Dade Behring, Inc. · Mar 3, 2006
Cited as a Predicate
4 later 510(k) summaries name this device as a predicate- Dimension LOCI Thyroid Stimulating Hormone Flex reagent cartridge (TSHL); Dimension LOCI Free Thyroxine Flex reagent…K243570 · Siemens Healthcare Diagnostics · Apr 25, 2025
- Dimension Exl With Lm SystemK130276 · Siemens Healthcare Diagnostics, Inc. · Mar 22, 2013
- Dimension Exl Loci Thyroid Calibrator, Model Rc 610AK100778 · Siemens Healthcare Diagnostics · May 5, 2010
- Loci Thyroid Calibrator With Model RC610K081103 · Siemens Healthcare Diagnostics, Inc. · May 23, 2008
Recalls
Recalls FDA ties to K073604, newest first; each opens FDA's recall record| Apr 2, 2015 | Z-1615-2015Certain Dimension Integrated Chemistry Systems Instrument Power Configurations may have been installed with a non-standard instrument power plug.The use of a non-standard plug configuration as described may lead to a… | Terminated |
| May 27, 2014 | Z-2133-2014There is a misassembly issue with the photometer installed on Dimension Integrated Chemistry Systems instruments. Through internal investigation by Siemens Healthcare Diagnostics has confirmed that a limited number of… | Terminated |
| Feb 27, 2013 | Z-1047-2013Through investigation of customer complaints, Siemens Healthcare Diagnostics has confirmed an increase in System Check failures due to high System Check LOCI results. Upon further investigation, Siemens has determined… | Terminated |
| Feb 27, 2013 | Z-1048-2013Through investigation of customer complaints, Siemens Healthcare Diagnostics has confirmed an increase in System Check failures due to high System Check LOCI results. Upon further investigation, Siemens has determined… | Terminated |
| Feb 27, 2013 | Z-1046-2013Through investigation of customer complaints, Siemens Healthcare Diagnostics has confirmed an increase in System Check failures due to high System Check LOCI results. Upon further investigation, Siemens has determined… | Terminated |
| Apr 12, 2010 | Z-0458-2011Some LOCI cartridges have sub-optimal seal of the lidstock that can cause rupture of the package at high elevations, causing the cartridge to leak. Use of leaking cartridges may result in inaccurate test results. | Terminated |
| Sep 30, 2008 | Z-0581-2009Error messages, "Wash Aspirator Failure" and "Wash station unable to recover" are not generated when one or both HM wash probes are totally occluded. | Terminated |
Other CEC Clearances
The newest 510(k)s for the same product code; see every CEC device- Access Free T4K240273 · Beckman Coulter, Inc. · Mar 6, 2024
- Elecsys FT4 IVK220456 · Roche Diagnostics · Apr 7, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 21, 2007
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1695
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files