Hemostatic Wound Dressing Without Thrombin Or Other Biologics. 510(k) K123387, from Z-Medica, LLC (Wallingford, CT). Product code QSY, class U.
As of Nov 18, 2026, K123387 is an FDA 510(k) held by Z-Medica, LLC, substantially equivalent on Apr 12, 2013 after 161 days, with 2 recalls tied to it in FDA's recall database.
- Substantially equivalent: Apr 12, 2013
- Review time: 161 days
- Recalls: 2
- Cited as a predicate by: 5 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFQuikClot® Hemostatic Dressing is intended for use as a topical dressing for local management of bleeding wounds such as cuts, lacerations and abrasions. It may also be used for temporary treatment of severely bleeding wounds such as surgical wounds (operative, postoperative, dermatological, etc.) and traumatic injuries. AND/OR
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Quikclot ExK072474 · Z-Medica Corporation · Oct 16, 2007
- Hemcon Chitoflex-Surgical DressingK071519 · Hemcon, Inc. · Aug 6, 2007
Cited as a Predicate
5 later 510(k) summaries name this device as a predicate- BloodSTOP iX Trauma Matrix (TM-iX-20)K253017 · Lifescience Plus, Inc. · Apr 30, 2026
- Ganymede 2cm diameter (FG100300); Ganymede 5cm x 5cm (FG100400); Ganymede 10cm x 10cm (FG100500); Ganymede 15cm x 15cm…K251700 · Speciality Fibres and Materials Limited · Feb 26, 2026
- Nustat XRK160578 · Beeken Biomedical, LLC · Jun 29, 2016
- HEMO-BandageK151204 · Coreleader Biotech Co., Ltd. · Jul 31, 2015
- D2 Hemostantic DressingK140757 · Z-Medica, LLC · Jul 17, 2014
Recalls
Recalls FDA ties to K123387, newest first; each opens FDA's recall record| Nov 17, 2017 | Z-0925-2018A customer complained that one of the pouches in a box of 10 had "QuikClot Roll" pouch instead of "QuikClot TraumaPad" pouch. The carton as well as the remaining 9 pouches were properly identified as QuikClot Trauma… | Terminated |
| May 17, 2017 | Z-2612-2017Packaging breach may compromise sterility | Terminated |
Other QSY Clearances
The newest 510(k)s for the same product code; their median review was 223 days; see every QSY device- BloodSTOP iX Trauma Matrix (TM-iX-20)K253017 · Lifescience Plus, Inc. · Apr 30, 2026
- Ganymede 2cm diameter (FG100300); Ganymede 5cm x 5cm (FG100400); Ganymede 10cm x 10cm (FG100500); Ganymede 15cm x 15cm…K251700 · Speciality Fibres and Materials Limited · Feb 26, 2026
- Mfuse (MS001)K250319 · Machina Medical, Inc. · Dec 15, 2025
- TRAUMAGEL® 2.0 Hemostatic GelK253609 · Cresilon, Inc. · Dec 12, 2025
- Traumagel®K240713 · Cresilon, Inc. · Aug 14, 2024
- Polysaccharide Hemostatic Powder (HP-2, HP-3, HP-5)K240097 · Ushare Medical, Inc. · May 22, 2024
- Hemoblock_S (Prescription); Hemoblock_S (OTC)K232216 · Incore Co., Ltd. · Apr 19, 2024
- RESPONDER® Polysaccharide HemostatK240454 · Starch Medical, Inc. · Mar 15, 2024
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 2, 2012
- Review panel
- Unknown
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files