Traumagel®
Hemostatic Wound Dressing Without Thrombin Or Other Biologics. 510(k) K240713, from Cresilon, Inc. (Brooklyn, NY). Product code QSY, class U.
As of Nov 18, 2026, K240713 is an FDA 510(k) held by Cresilon, Inc., substantially equivalent on Aug 14, 2024 after 152 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Aug 14, 2024
- Review time: 152 days
- Recalls: 0
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFTRAUMAGEL® is a hemostatic gel indicated for temporary external use for controlling moderate to severe bleeding.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Celox Gauze ProK113560 · Medtrade Products , Ltd. · Aug 1, 2012
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- TRAUMAGEL® 2.0 Hemostatic GelK253609 · Cresilon, Inc. · Dec 12, 2025
- Mfuse (MS001)K250319 · Machina Medical, Inc. · Dec 15, 2025
Other QSY Clearances
The newest 510(k)s for the same product code; their median review was 268 days; see every QSY device- BloodSTOP iX Trauma Matrix (TM-iX-20)K253017 · Lifescience Plus, Inc. · Apr 30, 2026
- Ganymede 2cm diameter (FG100300); Ganymede 5cm x 5cm (FG100400); Ganymede 10cm x 10cm (FG100500); Ganymede 15cm x 15cm…K251700 · Speciality Fibres and Materials Limited · Feb 26, 2026
- Mfuse (MS001)K250319 · Machina Medical, Inc. · Dec 15, 2025
- TRAUMAGEL® 2.0 Hemostatic GelK253609 · Cresilon, Inc. · Dec 12, 2025
- Polysaccharide Hemostatic Powder (HP-2, HP-3, HP-5)K240097 · Ushare Medical, Inc. · May 22, 2024
- Hemoblock_S (Prescription); Hemoblock_S (OTC)K232216 · Incore Co., Ltd. · Apr 19, 2024
- RESPONDER® Polysaccharide HemostatK240454 · Starch Medical, Inc. · Mar 15, 2024
- RESPONDER Polysaccharide HemostatK220525 · Starch Medical, Inc. · Dec 4, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Mar 15, 2024
- Review panel
- Unknown
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files