GE Innova/Innova Igs/Discovery Igs/Optima Angiographic, Fluoscopic X-Ray Systems With Cathlab Frontiers Solutions
Interventional Fluoroscopic X-Ray System. 510(k) K122457, from GE Healthcare (Buc, FR). Product code OWB, class 2.
As of Nov 19, 2026, K122457 is an FDA 510(k) held by GE Healthcare, substantially equivalent on Jan 2, 2013 after 142 days, with 20 recalls tied to it in FDA's recall database.
- Review time: 142 days
- Recalls: 20
- Cited as a predicate by: 2 devices
The angiographic X-ray systems are indicated for use for patients from newborn to geriatric in generating fluoroscopic and rotational images of human anatomy for cardiovascular, vascular and non-vascular, diagnostic and interventional procedures.
- GE Innova Solid State Xray Imager Flurosopic X Ray SystemK113034 · GE Healthcare · Dec 13, 2011
- Integrated Innova - S5I System OptionK111209 · GE Healthcare · Jul 26, 2011
- GE Discovery Igs Angiographic,Fluoroscopic X-Ray SystemK113403 · GE Medical Systems SCS · Feb 14, 2012
- Innova IGS 5, Innova IGS 6, Discovery IGS 7, Discovery IGS 7 ORK181403 · GE Healthcare · Nov 2, 2018
- Discovery Igs 740K133278 · GE Medical Systems SCS · Apr 24, 2014
| Mar 15, 2019 | Z-1200-2019There is a potential for loss of the x-ray imaging function when the user changes field of view (FOV) from 30cm to 20cm or from 20cm to 30cm while releasing the fluoroscopy footswitch pedal simultaneously. | Open |
| Mar 29, 2018 | Z-2387-2018, Z-2386-2018The Discovery IGS and Innova IGS systems may experience X-ray abort errors which could result in the loss of imaging mode before or during fluoroscopic use. | Terminated |
| Dec 18, 2015 | Z-0763-2016GE Healthcare has recently become aware of a reported incident in which a Mavig suspension arm with monitor assembly fell to the floor. | Terminated |
| Nov 13, 2015 | Z-0413-2016GE Healthcare has recently become aware of a potential safety issue related to a non-recoverable loss of displayed imaging (loss of monitor video) involving Optima CL323i & Optima IGS 320 systems . | Terminated |
| Nov 13, 2015 | Z-0414-2016GE Healthcare has recently become aware of a potential safety issue related to a non-recoverable loss of displayed imaging (loss of monitor video) involving Optima CL323i & Optima IGS 320 systems. | Terminated |
| May 29, 2015 | Z-1979-2015, Z-1977-2015, Z-1974-2015, Z-1982-2015, Z-1985-2015, Z-1980-2015, Z-1973-2015, Z-1978-2015, Z-1984-2015, Z-1981-2015, Z-1976-2015, Z-1983-2015GE Healthcare has recently become aware of a potential safety issue that may result in the loss of C-arm gantry motion capability on fluoroscopic Interventional imaging systems (Innova, Optima and Discovery). | Terminated |
| Sep 4, 2014 | Z-0451-2015Loss of imaging - affected devices may experience a loss of real-time interventional imaging and/or gantry motion due to the Electromagnetic (EM) sensitivity of the grid detection mechanism. | Terminated |
| Nov 15, 2013 | Z-0853-2014GE Healthcare has recently become aware of a potential safety issue with respect to IGS 630 Imaging Systems. While performing fluoroscopy on a biplane fluoroscopy unit, there is a potential for loss of the x-ray imaging… | Terminated |
- uAngio AVIVA CXK253726 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 21, 2026
- Extron 3;Extron 6K261413 · DRTECH Corporation · Aug 19, 2026
- Zenition 30K254205 · Philips Medical Systems Nederland B.V. · Aug 7, 2026
- Shield System (Siemens 30x40)K260607 · Radiaction , Ltd. · Jul 31, 2026
- SmartCT (R3.0 (L10))K253670 · Philips Medical Systems B.V. · Jul 10, 2026
- C-beamK252735 · Pulmera, Inc. · May 22, 2026
- Intelligent NRK252503 · Canon, Inc. · Apr 30, 2026
- ARTIS icono floor; ARTIS icono biplane; ARTIS icono ceiling; ARTIS phenoK254173 · Siemens Medical Solutions USA, Inc. · Apr 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 13, 2012
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files