GE Discovery Igs Angiographic,Fluoroscopic X-Ray System
Interventional Fluoroscopic X-Ray System. 510(k) K113403, from GE Medical Systems SCS (Buc, FR). Product code OWB, class 2.
As of Nov 20, 2026, K113403 is an FDA 510(k) held by GE Medical Systems SCS, substantially equivalent on Feb 14, 2012 after 89 days, with 4 recalls tied to it in FDA's recall database.
- Review time: 89 days
- Recalls: 4
- Cited as a predicate by: 2 devices
The angiographic X-ray systems are indicated for use in generating fluoroscopic and rotational-images of human anatomy for cardiovascular, vascular and non-vascular, diagnostic and interventional procedures. Additionally, with the OR table, the angiographic X-ray systems are indicated for use in generating fluoroscopic and rotational images of human anatomy for image-guided surgical procedures.
- Integrated Innova - S5I System OptionK111209 · GE Healthcare · Jul 26, 2011
- Artis Zee / Zeegos With SW VC14K090745 · Siemens Medical Solutions USA, Inc. · Jun 18, 2009
- Discovery Igs 740K133278 · GE Medical Systems SCS · Apr 24, 2014
- GE Innova/Innova Igs/Discovery Igs/Optima Angiographic, Fluoscopic X-Ray Systems With Cathlab Frontiers SolutionsK122457 · GE Healthcare · Jan 2, 2013
| Mar 29, 2018 | Z-2386-2018The Discovery IGS and Innova IGS systems may experience X-ray abort errors which could result in the loss of imaging mode before or during fluoroscopic use. | Terminated |
| Apr 15, 2016 | Z-1706-2016Potential non-recoverable loss of image acquisition. The affected Discovery systems may experience multiple X-Ray abort errors before or during a real-time fluoroscopic Interventional procedure. | Terminated |
| Dec 10, 2014 | Z-0966-2015Potential unintentional system motion or rotation due to a positioning user interface issue with Discovery IGS 730 and 740 products. | Terminated |
| Jun 19, 2013 | Z-2253-2013GE Healthcare has recently become aware of a potential safety issue with respect to Discovery IGS 730 Imaging Systems. A patient data management error may prevent the Discovery IGS 730 Imaging System from booting on… | Terminated |
- uAngio AVIVA CXK253726 · Shanghai United Imaging Healthcare Co., Ltd. · Aug 21, 2026
- Extron 3;Extron 6K261413 · DRTECH Corporation · Aug 19, 2026
- Zenition 30K254205 · Philips Medical Systems Nederland B.V. · Aug 7, 2026
- Shield System (Siemens 30x40)K260607 · Radiaction , Ltd. · Jul 31, 2026
- SmartCT (R3.0 (L10))K253670 · Philips Medical Systems B.V. · Jul 10, 2026
- C-beamK252735 · Pulmera, Inc. · May 22, 2026
- Intelligent NRK252503 · Canon, Inc. · Apr 30, 2026
- ARTIS icono floor; ARTIS icono biplane; ARTIS icono ceiling; ARTIS phenoK254173 · Siemens Medical Solutions USA, Inc. · Apr 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 17, 2011
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files