Hepatitis A Test (Antibody And Igm Antibody). 510(k) K113704, from Abbott Laboratories (Abbott Park, IL). Product code LOL, class 2.

As of Nov 21, 2026, K113704 is an FDA 510(k) held by Abbott Laboratories, substantially equivalent on Jun 28, 2012 after 195 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 195 days
  • Recalls: 2
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

ARCHITECT HAVAB-G The ARCHITECT HAVAB-G assay is a chemiluminescent microparticle immunoassay (CMIA) for the qualitative detection of IgG antibody to hepatitis A virus (IgG anti-HAV) in human adult and pediatric serum from patients with signs and symptoms or at risk for hepatitis. The ARCHITECT HAVAB-G assay is used to determine the immune status of individuals to hepatitis A virus infection.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K113704, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Mar 9, 2020Z-1728-2020An erroneous concentration value for hepatitis A virus was utilized during manufacture, leading to a decreased amount of antigen used for the impacted lots.Terminated
Nov 7, 2019Z-0574-2020Abbott has identified that Calibrator lot 08219BE00 is potentially impacted by an increase in Relative Light Units (RLUs) up to 94%. It has been confirmed that the increase in the calibrator RLU values may cause a…Terminated

Other LOL clearances

The newest 510(k)s for the same product code; their median review was 214 days; see every LOL device

Record

Type
Traditional
Received
Dec 16, 2011
Review panel
Microbiology
Regulation
21 CFR 866.3310

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files