Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days. 510(k) K113277, from Arrow International, Inc. (Reading, PA). Product code LJS, class 2.

As of Nov 19, 2026, K113277 is an FDA 510(k) held by Arrow International, Inc., substantially equivalent on Jun 21, 2012 after 227 days, with 6 recalls tied to it in FDA's recall database.

  • Review time: 227 days
  • Recalls: 6
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The ArrowADVANTAGE™ Pressure Injectable PICC is indicated for short-term or long-term peripheral access to the central venous system for intravenous therapy, blood sampling, infusion, pressure injection of contrast media, and allows for central venous pressure monitoring.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K113277, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 21, 2026Z-2378-2026Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if…Open
Dec 20, 2019Z-1254-2020Product lidstock contains the incorrect expiration date for the productTerminated
Apr 11, 2018Z-2023-2018Product sterility may be compromised due to unsealed packaging.Terminated
Jul 25, 2017Z-0602-2018Finished good kits may contain incorrect components. Kits that should contain a 5 FR 2 lumen catheter may contain a 4 FR single lumen catheter and kits that should contain a 4 FR single lumen catheter may contain a 5 FR…Terminated
Jun 1, 2017Z-0182-2018There is a possibility that the finished good kits may contain 5 Fr peel-away sheaths instead of the required 4 Fr peel-away sheaths.Terminated
Oct 16, 2015Z-0207-2016Possibility that the catheter peel-away component hub tabs may prematurely detach when the practitioner begins to peel apart the sheath body from the catheter. Although the issue does not pose a significant risk to the…Terminated

Other LJS clearances

The newest 510(k)s for the same product code; their median review was 202 days; see every LJS device

Record

Type
Traditional
Received
Nov 7, 2011
Review panel
General Hospital
Regulation
21 CFR 880.5970

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files