AU5800(R) Chemistry Analyzer
Electrode, Ion Specific, Potassium. 510(k) K112412, from Beckman Coulter, Inc. (Brea, CA). Product code CEM, class 2.
As of Nov 17, 2026, K112412 is an FDA 510(k) held by Beckman Coulter, Inc., substantially equivalent on Dec 23, 2011 after 123 days, with 7 recalls tied to it in FDA's recall database.
- Substantially equivalent: Dec 23, 2011
- Review time: 123 days
- Recalls: 7
- Cited as a predicate by: 2 devices
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Olympus AU2700 Clinical Chemistry AnalyzerK002982 · Olympus America, Inc. · Oct 25, 2000
- Olympus Lyophilized Chemistry Calibrators DR0070 And DR0071K043460 · Olympus America, Inc. · Jan 31, 2005
- Modification To Olympus AU2700 Clinical Chemistry AnalyzerK003721 · Olympus America, Inc. · Dec 18, 2000
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- CRP VarioK192118 · SENTINEL CH. SpA · Nov 8, 2019
- ISE Reagent, Glucose, CRP Latex, DxC 700 AU Clinical Chemistry AnalyzerK161837 · Beckman Coulter, Inc. · Dec 16, 2016
Recalls
Recalls FDA ties to K112412, newest first; each opens FDA's recall record| Feb 13, 2017 | Z-1704-2017Beckman Coulter is recalling the Rack ID Labels because the Rack ID number displayed and the Rack ID barcode label do not match. | Terminated |
| Jul 30, 2015 | Z-2310-2016Beckman coulter has received complaints regarding leaking and cracked C cups. When the cup cracks, coolant can leak onto the connectors of the Printed Circuit Boards (PCB) in the analyzer, resulting in a short-circuit… | Terminated |
| Sep 9, 2013 | Z-0153-2014The recall was initiated because Beckman Coulter has confirmed that some AU Clinical Chemistry Analyzer ISE units can experience premature ISE REF (Reference) valve failure. Premature valve failure can be detected by… | Terminated |
| Jun 3, 2013 | Z-1834-2013The recall was initiated because Beckman Coulter has identified a software error on AU5800 analyzers with the Automation Ready (AR) Sampler Kit. This software error results in the failure of the concentrated wash… | Terminated |
| Mar 20, 2013 | Z-1167-2013Beckman Coulter, Inc. initiated this recall because there is a software error that has the potential to cause the reporting of erroneous patient results because of misidentification by the AU5800 system. | Terminated |
| Nov 28, 2012 | Z-0913-2013Due to a software data storage limitation which only occurs under certain conditions, measurements of the Reagent Blank (RB) or Calibration (CAL) sample results are not saved and the software reverts to a previously… | Terminated |
| Oct 26, 2012 | Z-1873-2013Beckman Coulter is recalling the AU8500 Clinical Chemistry Analyzer because there is no labeling on the diluted detergent tank to show the proper disposition of the on/off valve. | Terminated |
Other CEM Clearances
The newest 510(k)s for the same product code; their median review was 273 days; see every CEM device- ISE indirect K for Gen.2; ISE indirect Na for Gen.2; ISE indirect Cl for Gen.2; cobas pro…K253491 · Roche Diagnostics · Feb 12, 2026
- ABL90 FLEX PLUS SystemK241037 · Radiometer Medicals Aps · Jan 14, 2025
- EasyStat 300K220396 · Medica Corporation · Sep 26, 2023
- ISE ElectrodesK230890 · Randox Laboratories, Ltd. · Sep 8, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 22, 2011
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1600
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files