Sensation(Tm) Plus 8FR. 50CC Intra-Aortic Balloon Catheter and Accessories
System, Balloon, Intra-Aortic And Control. 510(k) K112327, from Cardiac Assist, Maquet Cardiovascular, LLC (Manwah, NJ). Product code DSP, class 2.
As of Nov 28, 2026, K112327 is an FDA 510(k) held by Cardiac Assist, Maquet Cardiovascular, LLC, substantially equivalent on Sep 9, 2011 after 28 days, with 1 recall tied to it in FDA's recall database.
- Review time: 28 days
- Recalls: 1
- Cited as a predicate by: 2 devices
Refractory Unstable Angina. • Impending Infarction. • Acute Myocardial Infarction. • Refractory Ventricular Failure. - Complications of Acute MI (ie. Acute MR or VSD or papillary muscle rupture) • Cardiogenic Shock. • Support for diagnostic, percutaneous revascularization and interventional procedures. • Ischemia related intractable ventricular arrhythmias. • Septic Shock.
- Datascope Fiber Optic Pressure Sensor Intra-Aortic Balloon Catheter and CS300 Intra-Aortic Balloon Pump Control SystemK063525 · Datascope Corp. · Jan 5, 2007
- Datascope's 8FR. 50CC Intra-Aortic Balloon Catheter and Accessories, Models 0684,00-0498-01, 02K091449 · Datascope Corp., Cardiac Assist Division · Jun 18, 2009
- Mega 8FR. 50CC and Sensation Plus 8FR. 50CC Intra-Aortic Balloon Catheters and AccessoriesK133074 · Datascope Corp. · Dec 12, 2013
- Sensation Plus 7.5FR. 40CC Intra-Aortic Balloon (Iab) Catheter and AccessoriesK122628 · Datascope Corp., Cardiac Assist Division · Sep 6, 2012
| Started | Recall | Status |
|---|---|---|
| Sep 17, 2024 | Z-0311-2025There is discrepant labeling on the inner and outer packaging of the device. | Open |
- AC3™ Range™ Intra-Aortic Balloon PumpK250542 · Arrow International, LLC · Mar 26, 2025
- AC3™ Series IABPK232343 · Arrow International, LLC · Aug 30, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Aug 12, 2011
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.3535
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files