V60 Ventilator With Ppv and Auto-Trak+ Software Options
Continuous, Minimal Ventilatory Support, Facility Use Ventilator. 510(k) K102985, from Respironics, Inc. (Murrysville, PA). Product code MNT, class 2.
As of Nov 20, 2026, K102985 is an FDA 510(k) held by Respironics, Inc., substantially equivalent on Apr 5, 2011 after 180 days, with 9 recalls tied to it in FDA's recall database.
- Review time: 180 days
- Recalls: 9
- Cited as a predicate by: 2 devices
The V60 Ventilator with Proportional Pressure Ventilation and Auto-Trak+ Software Options is an assist ventilator and is intended to augment patient breathing. It is intended for spontaneously breathing individuals who require mechanical ventilation: patients with respiratory failure, chronic respiratory insufficiency, or obstructive sleep apnea in a hospital or other institutional setting under…
- V60 Ventilator, Model V8000K082660 · Respironics California, Inc. · Jan 9, 2009
- Servo-air Lite Ventilator SystemK230173 · Maquet Critical Care AB · Jul 6, 2023
- Nihon Kohden NKV-330 Ventilator SystemK213521 · Nihon Kohden Orangemed, Inc. · Jul 1, 2022
| Aug 25, 2023 | Z-2631-2023Power Management PCBAs may malfunction, causing a power failure leading to ventilator loss of function. | Open |
| Feb 28, 2022 | Z-0908-2022, Z-0907-2022Ventilator units have an issue impacting an internal electrical circuit within the ventilators, that in some cases could result in the ventilator ceasing to operate. | Open |
| Jan 24, 2022 | Z-0663-2022, Z-0662-2022A limited number of ventilators were assembled with expired adhesive. If the adhesive fails, a bracket may become loose and potentially damage the capacitors, which could cause the ventilator to stop providing… | Open |
| Apr 24, 2017 | Z-2061-2017Over time, low-frequency vibrations can cause the pins within the female connectors on the Motor Controller to Data Acquisition Board ribbon cable to become partially displaced causing momentary high resistance that… | Terminated |
| Feb 1, 2017 | Z-1687-2017The V60 Ventilator with Version 2.20 software installed may falsely detect that the blower motor has stalled. If this condition occurs, the software will cause the ventilator to shut down (Vent Inop) and display Error… | Terminated |
| Jun 4, 2013 | Z-1537-2013Respironics California, Inc. has initiated a recall on the V60 ventilator because of an issue with the software on the V60 Power Management Board Assembly. If a component fails on the Power Management Board Assembly, it… | Terminated |
| Jul 31, 2012 | Z-2260-2012Respironics is recalling the V60 ventilator because certain blower motor assemblies in the V60 ventilators may not meet specifications. Specifically, the impeller may not be properly seated on the blower motor shaft.… | Terminated |
- SV70 Ventilator (SV70)K252182 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Apr 6, 2026
- HFT750UK242931 · Mekics Co., Ltd. · May 15, 2025
- Vivo 3K240779 · Breas Medical AB · Dec 13, 2024
- F&P Airvo 3 NIV (PT311US)K233643 · Fisher & Paykel Healthcare, Ltd. · Aug 9, 2024
- Servo-air Lite Ventilator SystemK230173 · Maquet Critical Care AB · Jul 6, 2023
- Nihon Kohden NKV-330 Ventilator SystemK213521 · Nihon Kohden Orangemed, Inc. · Jul 1, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Oct 7, 2010
- Review panel
- Anesthesiology
- Regulation
- 21 CFR 868.5895
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files