Implant, Endosseous, Root-Form. 510(k) K101977, from Zimmer Dental, Inc. (Carlsbad, CA). Product code DZE, class 2.

As of Nov 19, 2026, K101977 is an FDA 510(k) held by Zimmer Dental, Inc., substantially equivalent on Sep 14, 2010 after 62 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 62 days
  • Recalls: 3
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Tapered Screw-Vent® T Implants are designed for use in the maxilla or mandible for immediate loading or for loading after a conventional healing period. Implants may be used to replace one or more missing SEP 14 2010 *:* *Tapered Screw-Vent® T Implant* 510(k) No. 510(k) No. _____ Page No. _____ A5-2 teeth.

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K101977, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Nov 29, 2017Z-1189-2018Two lots of the Tapered Screw-Vent Implants, with different outer thread diameters, were inadvertently commingled during the manufacturing process and may be mislabeled.Terminated
Nov 20, 2017Z-0284-2018Some implant vial caps in the recalled implant lot may inadvertently crack as the result of a manufacturing assembly condition.Terminated
Jun 25, 2014Z-2050-2014Zimmer Dental is conducting a voluntary recall of a single lot of the Tapered Screw-Vent Implant, Catalog Number TSVT6B13, Lot number 62284006, due to a potential crack in the cap of the outer vial.Terminated

Other DZE clearances

The newest 510(k)s for the same product code; their median review was 257 days; see every DZE device

Record

Type
Traditional
Received
Jul 14, 2010
Review panel
Dental
Regulation
21 CFR 872.3640

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files