Olympus GF Type UC180, Olympus GF Type UCT180 Evis Exera Ii Ulatrasound Gastrovideoscope

System, Imaging, Pulsed Doppler, Ultrasonic. 510(k) K093395, from Olympus Medical Systems Corporation (Center Valley, PA). Product code IYN, class 2.

As of Nov 19, 2026, K093395 is an FDA 510(k) held by Olympus Medical Systems Corporation, substantially equivalent on Jun 17, 2010 after 230 days, with 4 recalls tied to it in FDA's recall database.

  • Review time: 230 days
  • Recalls: 4
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

This instrument has been designed to be used with an Olympus universal endoscopic ultrasound center or a diagnostic ultrasound system (ALOKA CO. LTD), video system center, light source, documentation equipment, monitor, EndoTherapy accessories and other ancillary equipment.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K093395, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Sep 25, 2023Z-0333-2024Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for…Open
Oct 16, 2020Z-0500-2021A new inspection step was added to the cleaning and disinfection section of the Instructions For Use (IFU) for this device in order to reduce the risk of causing patient infections.Terminated
Dec 17, 2018Z-1007-2019The adhesive used in the repair of the endoscope was incorrectly prepared. It is unknown what affect the nonconforming adhesive mixture would have on the durability or effectiveness of the gluing operation for the…Terminated
Aug 21, 2015Z-2818-2015Insufficient information for specific cleaning accessories used for the cleaning and reprocessing of the GF-UCT180 ultrasound endoscopeTerminated

Other IYN clearances

The newest 510(k)s for the same product code; their median review was 134 days; see every IYN device

Record

Type
Traditional
Received
Oct 30, 2009
Review panel
Radiology
Regulation
21 CFR 892.1550

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files