Opti Cca-Ts, B-Lac Cassette Model BP7561

Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph. 510(k) K093280, from Opti Medical Systems, Inc. (Roswell, GA). Product code CHL, class 2.

As of Nov 20, 2026, K093280 is an FDA 510(k) held by Opti Medical Systems, Inc., substantially equivalent on Jan 7, 2011 after 444 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 444 days
  • Recalls: 1
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The OPTI CCA-TS B-Lac cassette is intended to be used for in vitro measurements of pH, PCO_{2 , PO_{2 , lactate (lactic acid), total hemoglobin (tHb), and oxygen saturation ( SO_{2 ), in heparinized whole blood samples (either arterial or venous) on the OPTI CCA-TS system, in either a clinical setting or point-of-care locations.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K093280, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Jul 3, 2012Z-2440-2012The values reported for PCO2 by BP7561 B-Lac cassettes are biased at high concentrations when used at altitudes above 2800 feet (853 meters).Terminated

Other CHL clearances

The newest 510(k)s for the same product code; their median review was 267 days; see every CHL device

Record

Type
Traditional
Received
Oct 20, 2009
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1120

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files