Blood Collection Tube Samples For Use With Point Of Care Blood Analyzer
Electrode, Ion Specific, Potassium. 510(k) K092849, from Epocal, Inc. (Ottawa, CA). Product code CEM, class 2.
As of Nov 17, 2026, K092849 is an FDA 510(k) held by Epocal, Inc., substantially equivalent on Mar 30, 2010 after 195 days, with no recalls tied to it in FDA's recall database.
- Substantially equivalent: Mar 30, 2010
- Review time: 195 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe epoc Blood Analysis System is intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or capillary whole blood in the laboratory or at the point of care in hospitals, nursing homes or other clinical care institutions.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Epoc Blood Analysis SystemK061597 · Epocal, Inc. · Sep 27, 2006
- Blood Gas, Electrolyte And Metabolite Test CardK090109 · Epocal, Inc. · Jun 24, 2009
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- epoc Blood Analysis SystemK200107 · Epocal, Inc. · Jun 5, 2020
Other CEM Clearances
The newest 510(k)s for the same product code; their median review was 273 days; see every CEM device- ISE indirect K for Gen.2; ISE indirect Na for Gen.2; ISE indirect Cl for Gen.2; cobas pro…K253491 · Roche Diagnostics · Feb 12, 2026
- ABL90 FLEX PLUS SystemK241037 · Radiometer Medicals Aps · Jan 14, 2025
- EasyStat 300K220396 · Medica Corporation · Sep 26, 2023
- ISE ElectrodesK230890 · Randox Laboratories, Ltd. · Sep 8, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Sep 16, 2009
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1600
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files