Neuviz 16 Multi-Slice Ct Scanner System
System, X-Ray, Tomography, Computed. 510(k) K092742, from Neusoft Medical Systems Co., Ltd. (Shenyang, Liaoning, CN). Product code JAK, class 2.
As of Nov 17, 2026, K092742 is an FDA 510(k) held by Neusoft Medical Systems Co., Ltd., substantially equivalent on Sep 22, 2009 after 14 days, with 5 recalls tied to it in FDA's recall database.
- Substantially equivalent: Sep 22, 2009
- Review time: 14 days
- Recalls: 5
- Cited as a predicate by: 2 devices
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe NeuViz 16 Multi-Slice CT Scanner System can be used as a whole body computed tomography X-ray system featuring a continuously rotating X-ray tube and detector array with multislice capability up to 16 slices simultaneously. The acquired X-RAY transmission data is reconstructed by computer into cross-sectional imagers of the body from the same axial plane taken at different angles.
Cited as a Predicate
2 later 510(k) summaries name this device as a predicate- NeuViz 16 Essence Multi-slice CT Scanner SystemK171198 · Neusoft Medical Systems Co., Ltd. · Dec 7, 2017
- Neuviz 64 Multi-Slice Ct Scanner SystemK121792 · Neusoft Medical Systems Co., Ltd. · Nov 16, 2012
Recalls
Recalls FDA ties to K092742, newest first; each opens FDA's recall record| Mar 24, 2016 | Z-1573-2016The following issues are found in NeuViz 16 systems with software version 1.1.4.21425 and version 1.1.4.21426: 1) During the filming operation on MX 16-slice console software, the clipboard used for copying and pasting… | Terminated |
| Mar 4, 2013 | Z-1165-2013User error of the NeuViz 16 or NeuViz Dual may cause personnel injuries. There was a report where a finger was pinched when the table was moved backward while the tabletop was controlled by another person from the… | Terminated |
| Oct 18, 2012 | Z-0466-2013The four screws that secure the patient table top to the carrier pulled out and caused the table top to detach. This issue may affect NeuViz Dual and NeuViz 16 scanners. | Terminated |
| Jun 8, 2012 | Z-2083-2012One of the four screws that secure the Oil-accumulator to the X-Ray Tube pulled out in the NeuViz 16 CT scanner, which caused the Oil-accumulator to detach. | Terminated |
| Feb 9, 2011 | Z-2241-2011Dimension measurement displays on a combined image were found inaccurate after the clinician merged multiple image series into one image. | Terminated |
Other JAK Clearances
The newest 510(k)s for the same product code; their median review was 237 days; see every JAK device- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Enhanced Boundary for PCCTK253560 · Ge Medical Systems, LLC · Jun 24, 2026
Record
- Type
- Traditional, third-party review
- Received
- Sep 8, 2009
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files