Abbott M2000SP and Abbott M2000RT, Models 9K14-01 (G-Series), 9K14-02 (E-Series), 9K1501

Real Time Nucleic Acid Amplification System. 510(k) K092705, from Abbott Molecular, Inc. (Des Plaines, IL). Product code OOI, class 2.

As of Nov 21, 2026, K092705 is an FDA 510(k) held by Abbott Molecular, Inc., substantially equivalent on May 28, 2010 after 267 days, with 7 recalls tied to it in FDA's recall database.

  • Review time: 267 days
  • Recalls: 7
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The Abbott $m2000$ system is intended for in vitro diagnostic use in performing FDA cleared and approved nucleic acid testing in clinical laboratories. It comprises the Abbott $m2000sp$ and the Abbott $m2000rt$ instruments. The Abbott m2000sp is an automated system for performing sample preparation for nucleic acid testing.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K092705, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Oct 23, 2014Z-0463-2015Some versions of Application Specifications (App Spec) are incompatible with m2000sp system software version 6.0 and 7.0. This issue will cause Error Code 9000 (An unexpected error has occurred: Software error) to be…Terminated
Jun 19, 2014Z-2169-2014Abbott Molecular identified that some of the 5 ml Reaction Vessels (RVs) contained in lots 56944001, 57026001, 57059001, and 57673001 (original vendor lot 2198077) may have an insufficient rim. An RV with an…Terminated
Nov 23, 2013Z-0948-2015The x-drive assembly may fail prematurely. This could cause the manipulator or liquid handling arm to contact an object, shake and drip, or improperly pipet.Terminated
Dec 4, 2012Z-0634-2013An issue with the m2000sp Instrument software has been identified whereby, after a series of steps, if changes are made to the control or calibrator information on the Sample Extraction Assay Details screen, the changes…Terminated
Jan 31, 2012Z-2013-2012In the Abbott Molecular Bar Code Scanner User's Guide, List Number 6L88-02/09, the section Modifying the Keyboard Format for Bar Code Scanner LN 6L89-01 contains incorrect bar codes that can prevent the correct…Terminated
Oct 11, 2011Z-0365-2012Abbott Molecular has received reports in which the liquid waste sensor and components in the m2000sp lower instrument cabinet overheated and/or caught fire.Terminated
Sep 8, 2011Z-0048-2012The Abbott m2000rt System software has software bug which can affect customers who manually enter a Test Order onto the m2000rt and sorts a column on the calibration or control grids of the Test Order screen by double…Terminated

Other OOI clearances

The newest 510(k)s for the same product code; their median review was 134 days; see every OOI device
  • RevogeneK243922 · Meridian Bioscience, Inc. · Mar 20, 2025
  • RevogeneK222779 · Meridian Bioscience, Inc. · Jan 26, 2023
  • RevogeneK220480 · Meridian Bioscience, Inc. · Jul 11, 2022

Record

Type
Traditional
Received
Sep 3, 2009
Review panel
Clinical Chemistry
Regulation
21 CFR 862.2570

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files