Mesh, Surgical. 510(k) K083898, from Tei Biosciences, Inc. (Boston, MA). Product code FTM, class 2.

As of Nov 19, 2026, K083898 is an FDA 510(k) held by Tei Biosciences, Inc., substantially equivalent on Feb 4, 2009 after 37 days, with 3 recalls tied to it in FDA's recall database.

  • Review time: 37 days
  • Recalls: 3
  • Cited as a predicate by: 4 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

SurgiMend is intended for implantation to reinforce soft tissue where weakness exists and for the surgical repair of damaged or ruptured soft tissue membranes. SurgiMend is specifically indicated for: • Plastic and reconstructive surgery • Muscle flap reinforcement - Hernia repair including abdominal, inguinal, femoral, diaphragmatic, scrotal, umbilical, and incisional hernias

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

4 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K083898, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
May 23, 2023Z-2072-2023, Z-2074-2023, Z-2075-2023Possible out of specification endotoxin test results due to issues with in-process and finished goods endotoxin testing.Open

Other FTM clearances

The newest 510(k)s for the same product code; their median review was 95 days; see every FTM device

Record

Type
Special
Received
Dec 29, 2008
Review panel
General, Plastic Surgery
Regulation
21 CFR 878.3300

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files