Philips Model Mx 16 Slice Ct System

System, X-Ray, Tomography, Computed. 510(k) K083498, from Philips Medical Systems (Cleveland), Inc. (Cleveland, OH). Product code JAK, class 2.

As of Nov 18, 2026, K083498 is an FDA 510(k) held by Philips Medical Systems (Cleveland), Inc., substantially equivalent on Dec 17, 2008 after 22 days, with 5 recalls tied to it in FDA's recall database.

  • Substantially equivalent: Dec 17, 2008
  • Review time: 22 days
  • Recalls: 5
  • Cited as a predicate by: 1 device

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The Philips MX 16-slice CT system can be used as a Head and Whole Body Computed Tomography X-ray System featuring a continuously rotating x-ray tube and detector array with multislice capability up to 16 slices simultaneously. The acquired x-ray transmission data is reconstructed by computer into cross-sectional images of the body from the same axial plane taken at different angles.

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K083498, newest first; each opens FDA's recall record
Oct 9, 2014Z-0190-2015"The orientation of images is displayed incorrectly. When operator chooses gantry on the right side from operation console, and the patient position is HFDL, HFDR, FFDL or FFDR, the patient position picture and text is…Terminated
Jul 22, 2013Z-0019-2014A pinch point at the end of the table top can cause injury.Terminated
Dec 19, 2012Z-0899-2013The four screws that secure the patient table top to the carrier became loose, which caused the table top to detach.Terminated
Aug 24, 2012Z-2386-2012On August 24, 2012 the firm recalled the MX 16-slice after discovering that a bolt which attaches the oil accumulator within the gantry may fail, resulting in the oil accumulator detaching from the tube housing assembly…Terminated
Mar 10, 2011Z-2059-2011The Philips MX 16-slice CT scanners are subject to recall/field correction due to a problem encountered with the units when using the 'Combine Viewing' Option. The firm determined that inaccurate dimension measurements…Terminated

Other JAK Clearances

The newest 510(k)s for the same product code; their median review was 237 days; see every JAK device

Record

Type
Traditional, third-party review
Received
Nov 25, 2008
Review panel
Radiology
Regulation
21 CFR 892.1750

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.