Ge Brightspeed Delight CT Scanner System
System, X-Ray, Tomography, Computed. 510(k) K082816, from Ge Medical Systems, LLC (Waukesha, WI). Product code JAK, class 2.
As of Nov 18, 2026, K082816 is an FDA 510(k) held by Ge Medical Systems, LLC, substantially equivalent on Oct 8, 2008 after 13 days, with 9 recalls tied to it in FDA's recall database.
- Review time: 13 days
- Recalls: 9
- Cited as a predicate by: 2 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFThe GE BrightSpeed Delight Series Computed Tomography X-ray system is intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different angles and planes, patient for all ages, including Axial, Cine, Helical, Cardiac, and Gated acquisitions. These images may be obtained either with or without contrast.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Starspeed Series CT Scanner SystemsK052855 · GE Healthcare · Oct 28, 2005
Cited as a predicate
2 later 510(k) summaries name this device as a predicate- Optima CT520K123596 · Ge Hangwei Medical Systems Co., Ltd. · Feb 8, 2013
- Discovery Model Nm/Ct 670K093514 · Ge Medical Systems F.I. Haifa · Dec 10, 2009
Recalls
Recalls FDA ties to K082816, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| May 24, 2018 | Z-2586-2018Some CT and CT/PET systems recently installed with a GE supplied A! electrical panel may not be properly wired to the partial system UPS (Uninteruptible Power Supply). | Terminated |
| Apr 27, 2018 | Z-2872-2018, Z-2873-2018GE Healthcare has identified that some CT systems may have a damaged cable that can expose 120VAC to Service Engineers working inside the gantry. | Terminated |
| May 19, 2017 | Z-2188-2017, Z-2186-2017It was discovered that an issue has been identified that can result in a scan starting before the prescribed delay has completed. | Terminated |
| Oct 9, 2013 | Z-0840-2014There is an issue with the Manual Film Composer feature on some CT products. There is an opportunity, while following a specific workflow, to create a film image with one patient's images and another patient's name in… | Terminated |
| Jan 19, 2011 | Z-2214-2011GE Healthcare has become aware of a potential set of circumstances that could cause X-ray continuation during an unexpected table stop on certain BrightSpeed systems (BrightSpeed Excel/Edge/Elite Select and BrightSpeed… | Terminated |
| Sep 3, 2010 | Z-0368-2011, Z-0369-2011GE has become aware of a potential set of circumstances that could cause x-ray continuation during an unexpected table stop on certain LightSpeed VCT and BrightSpeed systems. | Terminated |
Other JAK clearances
The newest 510(k)s for the same product code; their median review was 237 days; see every JAK device- AVIEW Aorta MetricsK260391 · Coreline Soft Co., Ltd. · Oct 16, 2026
- CAS-One IRK261225 · Cascination AG · Sep 29, 2026
- BodyTom 64 (NL4100); OmniTom Elite (NL5000)K261125 · Samsung HME America, Inc., dba NeuroLogica Corp. · Sep 22, 2026
- SCENARIA View Phase 6.0K261229 · Fujifilm Corporation · Sep 18, 2026
- FCT iStream Phase 2K253836 · Fujifilm Corporation · Sep 4, 2026
- BodyTom Elite (NL4000)K253450 · NeuroLogica Corp., a Samsung Company · Jul 28, 2026
- CardIQ SuiteK253770 · GE Medical Systems SCS · Jul 21, 2026
- Enhanced Boundary for PCCTK253560 · Ge Medical Systems, LLC · Jun 24, 2026
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Sep 25, 2008
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1750
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files