Heartsuite Hemodynamics 7.10

Computer, Diagnostic, Programmable. 510(k) K082421, from Emageon, Inc. (Hartland, WI). Product code DQK, class 2.

As of Nov 21, 2026, K082421 is an FDA 510(k) held by Emageon, Inc., substantially equivalent on Dec 17, 2008 after 117 days, with 11 recalls tied to it in FDA's recall database.

  • Review time: 117 days
  • Recalls: 11
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

HeartSuite Hemodynamics monitors, measures, and records physiologic data from a human patient undergoing a cardiac catheterization procedure. The Monitoring System is for the monitoring of vital parameters including ECG, SpO2, invasive blood pressure, temperature, NIBP and CO2, and for the evaluation of resting ECG, arrhythmias, ST-segments and cardiac output.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate
  • Merge HemoK152864 · Merge Healthcare Incorporated · Apr 7, 2016

Recalls

Recalls FDA ties to K082421, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 4, 2016Z-1778-2017Use of the software may show an incorrect value to the user when viewing the Fractional Flow Reserve (FFR) results during recording.Terminated
Apr 4, 2016Z-1457-2017In some instances, the system will lock tabs within a study, even when a second user does not have the study open on a different workstation.Terminated
Mar 28, 2016Z-1091-2017There is a potential connection issue when powering up the Merge Hemo Record Station and the Hemo Monitor does not communicate with the Client PC.Terminated
Mar 10, 2016Z-2707-2017If the PDM is utilized to output a pressure for computing fractional flow reserve (FFR), the analog output may not reflect the true representation of the selected pressure waveform being provided by the PDM to the Link…Terminated
Oct 26, 2015Z-0554-2016The firm, Merge Healthcare, sent out Merge HEMO V10.0 & Merge CARDIO V10.1 software to 3 customers before the product was completely validated in house.Terminated
May 31, 2015Z-1203-2017Non-invasive blood pressure pumps (NIBP) voltage is not sufficient and causes the NIBP pumps to fail prior to reaching adequate initial pressure.Terminated
Mar 30, 2015Z-1923-2017The units may display the alarm "sampling line clogged" after the flow zeroing procedure that is conducted automatically 1 hour after start up. This could result in the potential of a small bias added to the CO2…Terminated
Jan 21, 2015Z-2347-2015A system freeze-up of the Merge Hemo system, that included the PHASEIN End Tidal CO2 unit, resulted in the user needing to move the patient to another cath lab.Terminated
Sep 29, 2014Z-0143-2015It has been reported that during use, the SpO2 value displayed on the Hemo Monitor may not update to reflect changes in the patient's oxygen value. It is also possible that if using the pulse rate of the SpO2 finger…Terminated
Apr 30, 2014Z-0665-2017The application may crash during the cath lab procedure.Terminated
Jul 2, 2012Z-2341-2016The International Normalized Ratio (INR) value displayed in the study report does not match the value that is imported on the pre-procedure labs screen from HL7Terminated

Other DQK clearances

The newest 510(k)s for the same product code; their median review was 147 days; see every DQK device

Record

Type
Traditional, third-party review
Received
Aug 22, 2008
Review panel
Cardiovascular
Regulation
21 CFR 870.1425

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files