Arca
Skip to content
Tools
Tools

Biomet Sports Medicine Anchor Devices and Ziploop Constructs

Screw, Fixation, Bone. 510(k) K080088, from Biomet Manufacturing, Inc. (Warsaw, IN). Product code HWC, class 2.

As of Nov 20, 2026, K080088 is an FDA 510(k) held by Biomet Manufacturing, Inc., substantially equivalent on Jun 11, 2008 after 149 days, with 8 recalls tied to it in FDA's recall database.

  • Review time: 149 days
  • Recalls: 8
  • Cited as a predicate by: 4 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Ti-Screw, ALLthread™ Titanium, ALLthread™ PEEK and Hitch™ PEEK Anchors are indicated for soft tissue reattachment procedures in the shoulder, foot/ankle, elbow, knee, hand/wrist, and hip. Specific indications are as follows: Shoulder: Acromio-Clavicular Separation, Anterior Shoulder Instability Repair, Bankart Lesion Repairs, Biceps Tenodesis, Capsule Repair or Capsulolabral Reconstruction…

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

4 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K080088, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Feb 26, 2015Z-1364-2015The firm is recalling ToggleLocs and Ziploops manufactured in May and July of 2014 as they were not processed following a standard work process, which resulted in complaints of sterile packaging not being sealed.Terminated
Jan 25, 2012Z-1236-2012, Z-1235-2012, Z-1233-2012, Z-1237-2012, Z-1231-2012, Z-1232-2012, Z-1234-2012Biomet initiated this action following an internal audit which discovered the component level package insert was included in the product packaging in place of the end level product package insert (01-501072). This meant…Terminated

Other HWC clearances

The newest 510(k)s for the same product code; their median review was 157 days; see every HWC device

Record

Type
Traditional
Received
Jan 14, 2008
Review panel
Orthopedic
Regulation
21 CFR 888.3040

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files