Symbia-E, Model 10275879
System, Tomography, Computed, Emission. 510(k) K072567, from Siemens Medical Solutions USA, Inc. (Hoffman Estates, IL). Product code KPS, class 2.
As of Nov 18, 2026, K072567 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., substantially equivalent on Oct 30, 2007 after 48 days, with 2 recalls tied to it in FDA's recall database.
- Review time: 48 days
- Recalls: 2
- Cited as a predicate by: 2 devices
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFTo detect or image the distribution of radionuclides in the body or organ, using the following techniques: planar imaging, whole body imaging, tomographic imaging for isotopes with energies up to 588keV. Template D0006237 Rev A Page 13 DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 0CT 30 2007 Ms. M.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- E. Cam Profile Attenuation CorrectionK963983 · Siemens Corp. · Mar 31, 1997
- Siemens Enhanced Imaging SystemK041166 · Siemens Medical Solutions USA, Inc. · May 17, 2004
Cited as a predicate
2 later 510(k) summaries name this device as a predicate- Anyscan-S Spect Imaging SystemK131625 · Absolute Imaging Solutions · Oct 3, 2013
- Symbia, Version 4.0K082506 · Siemens Medical Solutions USA, Inc. · Nov 21, 2008
Recalls
Recalls FDA ties to K072567, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record| May 15, 2012 | Z-1686-2012Siemens has identified a potential patient safety issue for e.cam and Symbia E camera systems that have had the radial drive motor assembly replaced during a Service action. There is a remote chance that during the… | Terminated |
| Apr 11, 2012 | Z-1296-2015Radial motor drives replaced during a customer service action were incorrectly assembled backwards. | Terminated |
Other KPS clearances
The newest 510(k)s for the same product code; their median review was 88 days; see every KPS device- Micsi-PetK261305 · Microstructure Imaging, Inc. · Sep 11, 2026
- uMI Panvivo (uMI Panvivo M)K261427 · Shanghai United Imaging Healthcare Co., Ltd. · Jul 28, 2026
- Symbia Pro.specta Q3 (11364751);Symbia Pro.specta X3 (11364752);Symbia Pro.specta X7 (11364753);Symbia Pro.specta VA40…K261315 · Siemens Medical Solutions USA, Inc. · May 21, 2026
- uMI Panvivo (uMI Panvivo LS); uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI Panvivo S); uMI Panvivo (uMI Panvivo EX); uMI…K260524 · Shanghai United Imaging Healthcare Co., Ltd. · Apr 3, 2026
- uMI Panvivo (uMI Panvivo); uMI Panvivo (uMI Panvivo S); uMI Panvivo (uMI Panvivo EX); uMI Panvivo (uMI Panvivo ES)K253564 · Shanghai United Imaging Healthcare Co., Ltd. · Feb 13, 2026
- VERITON CT 300 Series Digital SPECT/CT System (VERITON CT 316/364); VERITON CT 400 Series Digital SPECT/CT System…K254001 · Spectrum Dynamics Medical, Ltd. · Jan 13, 2026
- AnyScan 3.0 NM Scanner FamilyK253844 · Mediso Medical Imaging Systems, Ltd. · Dec 30, 2025
- Cartesion Prime (PCD-1000A/3) V10.21K251370 · Canon Medical Systems Corporation · Dec 1, 2025
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Sep 12, 2007
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1200
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files