Arca
Skip to content
Tools
Tools

Modification To Giraffe and Panda Warmers (Giraffe and Panda Uninterruptible Power Supply)

Warmer, Infant Radiant. 510(k) K072157, from Ohmeda Medical (Laurel, MD). Product code FMT, class 2.

As of Nov 19, 2026, K072157 is an FDA 510(k) held by Ohmeda Medical, substantially equivalent on Aug 27, 2007 after 24 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 24 days
  • Recalls: 1
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Infant radiant warmers provide infrared heat in a controlled manner to neonates who are unable to thermo-regulate based on their own physiology. Infant radiant warmers may be used to facilitate the neonate’s transition to the external environment or to provide a controlled open environment.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K072157, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Nov 18, 2016Z-1507-2017Certain power cords could overheat. The affected power cords were manufactured by Electric-Cord and are referred to as Taller Bridge power cords. The overheating of the power cord could result in fire, charring, smoke,…Terminated

Other FMT clearances

The newest 510(k)s for the same product code; their median review was 118 days; see every FMT device

Record

Type
Special
Received
Aug 3, 2007
Review panel
General Hospital
Regulation
21 CFR 880.5130

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.