Gammamedplus Ix Series Hdr Afterloader
System, Applicator, Radionuclide, Remote-Controlled. 510(k) K071381, from Varian Medical Systems (Palo Alto, CA). Product code JAQ, class 2.
As of Nov 20, 2026, K071381 is an FDA 510(k) held by Varian Medical Systems, substantially equivalent on Jul 18, 2007 after 62 days, with no recalls tied to it in FDA's recall database.
- Review time: 62 days
- Recalls: 0
- Cited as a predicate by: 1 device
Both the GammaMedplus iX and GammaMedplus 3/24 iX are indicated, in the treatment of both benign and malignant disease, for both curative and palliative intent, in the delivery of remote controlled high dose rate brachytherapy for conditions anywhere in the body when brachytherapy treatment is indicated.
- Gammamed Plus High Dose Rate Remote Afterloading SystemK983436 · Gammamed USA · Oct 29, 1998
- Gammamed Plus 3/24 Hdr Remote AfterloaderK031524 · Varian Medical Systems, Inc. · Nov 26, 2003
- Gammamedplus Ix Brachytherapy Afterloader, Gammamedplus 3/24 Ix Brachytherapy AfterloaderK120993 · Varian Medical Systems, Inc. · Jul 26, 2012
- LumenCare AzureK262383 · Nucletron B.V. · Jul 24, 2026
- MAASTRO Rectal Applicator SetK252717 · Varian Medical Systems · May 20, 2026
- Rectal ApplicatorK251037 · Nucletron B.V. · Dec 19, 2025
- Guided Aarhus Applicator SetK252884 · Varian Medical Systems · Nov 19, 2025
- CT/ MR Tandem and Ovoid SetK250299 · Varian Medical Systems, Inc. · May 9, 2025
- Intracavitary/Interstitial SystemK250289 · Varian Medical Systems · Apr 25, 2025
- Titanium Flexible Geometry FSD Applicator Set (GM11013400)K243939 · Varian Medical Systems, Inc. · Mar 3, 2025
- Mould Probe MR SafeK241764 · Varian Medical Systems, Inc. · Jan 10, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 17, 2007
- Review panel
- Radiology
- Regulation
- 21 CFR 892.5700
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files