Aff (Mark I) Volumetric Infusion Pump

Pump, Infusion. 510(k) K070529, from Definitive Medical Technologies, Ltd. (Lod, IL). Product code FRN, class 2.

As of Nov 20, 2026, K070529 is an FDA 510(k) held by Definitive Medical Technologies, Ltd., substantially equivalent on May 8, 2007 after 74 days, with 5 recalls tied to it in FDA's recall database.

  • Review time: 74 days
  • Recalls: 5

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The AFF (MARK I) Volumetric Infusion Pump is indicated for delivering infusions of medications, as well as providing TPN (Total Parenteral Nutrition) and PCA (Patient Control Analgesia). It is intended for use in hospitals, ambulatory & nursing home (extended care) settings, and home care environments.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Recalls

Recalls FDA ties to K070529, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Jun 14, 2016Z-2219-2016, Z-2220-2016WalkMed Infusion, LLC Announces a Voluntary Field Action of the Triton Infusion Pump (model 300000) and Triton FP Infusion Pump (model 400000) Due to Unapproved Changes to the Software and Specifications of the Triton…Terminated
Oct 1, 2015Z-0242-2016The device might fail to detect air in line while infusing the medication Venofer. This may occur when a drop of Venofer gets stuck in the tubing adjacent to the bubble detector and the Total Volume Limit is programmed…Terminated
Feb 17, 2014Z-1122-2014WalkMed Infusion is initiaing a recall on their Triton FP Infusion Pump, Part Number 400000 due to the label on the right side of the pump containing an incorrect instruction.Terminated
Jun 17, 2010Z-0307-2011Pump door may be in a near shut position, but unlatched, and the "Door Open" alarm may not sound.Terminated

Other FRN clearances

The newest 510(k)s for the same product code; their median review was 242 days; see every FRN device

Record

Type
Traditional, third-party review
Received
Feb 23, 2007
Review panel
General Hospital
Regulation
21 CFR 880.5725

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files