Acuson Antares Diagnostic Ultrasound System
System, Imaging, Pulsed Doppler, Ultrasonic. 510(k) K063803, from Siemens Medical Solutions USA, Inc., Ultrasound DI (Mountain View, CA). Product code IYN, class 2.
As of Nov 19, 2026, K063803 is an FDA 510(k) held by Siemens Medical Solutions USA, Inc., Ultrasound DI, substantially equivalent on Jan 5, 2007 after 14 days, with 9 recalls tied to it in FDA's recall database.
- Review time: 14 days
- Recalls: 9
- Cited as a predicate by: 2 devices
- Modification To Acuson Antares Ultrasound SystemK063138 · Siemens Medical Solutions USA, Inc. · Nov 22, 2006
- Sonoline Antares Diagnostic Ultrasound SystemK050034 · Siemens Medical Solutions USA, Inc. · Jan 13, 2005
- Sonoline Antares With Clarify VeK033196 · Siemens Medical Solutions USA, Inc. · Oct 16, 2003
- V5MS TransducerK121807 · Siemens Medical Solutions USA, Inc. · Jul 10, 2012
- Acuson S2000 Ultrasound SystemK072786 · Siemens Medical Solutions USA, Inc. · Nov 13, 2007
| Aug 17, 2010 | Z-1836-2011There is an error in the estimation of mean pressure gradient in the Cardiac measurement package. The currently implemented calculation will result in an underestimation of the mean pressure gradient (PGmean) when… | Terminated |
| Mar 1, 2010 | Z-1853-2011Image captured from the device may be erroneous. | Terminated |
| Oct 2, 2009 | Z-1006-2011, Z-1005-2011, Z-1007-2011ECG waveform does not accurately align with 2D, M-Mode or Spectral Images. | Terminated |
| Mar 21, 2008 | Z-1766-2008, Z-1767-2008Software issue may result in distorted images and inaccurate measurements, which could lead to a misdiagnosis. | Terminated |
| Jul 10, 2007 | Z-0297-2008Image errors: A software problem results in on-screen indications (graphics) that lead the user to believe that the patient's right and left and the transducer orientation are oriented the same. This is not the case and… | Terminated |
| Jul 10, 2007 | Z-0298-2008Image error: A software problem results in on-screen indications (graphics) that lead the user to believe that the patient's right and left and the transducer orientation are oriented the same. This is not the case and… | Terminated |
- Diagnostic Ultrasound System (Nuewa A20W); Diagnostic Ultrasound System (Nuewa A20); Diagnostic Ultrasound System…K261585 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Oct 16, 2026
- Diagnostic Ultrasound System (Resona I10W);Diagnostic Ultrasound System (Resona I10 Exp);Diagnostic Ultrasound System…K261617 · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Oct 8, 2026
- V10 Diagnostic Ultrasound System; cV10 Diagnostic Ultrasound System; H10 Diagnostic Ultrasound System; XV10 Diagnostic…K263150 · Samsung Medison Co., Ltd. · Oct 8, 2026
- Voluson Expert 18; Voluson Expert 20; Voluson Expert 22K261933 · GE Medical Systems Ultrasound and Primary care Diagnostics, LLC · Oct 2, 2026
- EPIQ Inspira Series Diagnostic Ultrasound System; Affiniti Series Diagnostic Ultrasound SystemK262548 · Philips Ultrasound, LLC · Sep 25, 2026
- EVO X30 Diagnostic Ultrasound System; EVO X20 Diagnostic Ultrasound System; EVO X10 Diagnostic Ultrasound System; EVO…K263182 · Samsung Medison Co., Ltd. · Sep 25, 2026
- Vivid Explorer/Vivid Advanced/Vivid FocusK261313 · GE Medical Systems Ultrasound and Primary Care Diagnostics · Sep 2, 2026
- Digital Color Doppler Ultrasound System (Marvo 95/Marvo 95 Elite/Marvo 90/Marvo 90 CV/Marvo 90 Pro/Marvo 90 Exp/Marvo…K254027 · Sonoscape Medical Corp. · Aug 24, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional, third-party review
- Received
- Dec 22, 2006
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1550
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files