Dimension Vista Iga Flex Reagent Cartridge Assay
Method, Nephelometric, Immunoglobulins (G, A, M). 510(k) K061338, from Dade Behring, Inc. (Newark, DE). Product code CFN, class 2.
As of Nov 18, 2026, K061338 is an FDA 510(k) held by Dade Behring, Inc., substantially equivalent on Jul 6, 2006 after 52 days, with no recalls tied to it in FDA's recall database.
- Review time: 52 days
- Recalls: 0
- Cited as a predicate by: 1 device
Indications for use
As the 510(k) summary states them, read from FDA's summary PDFK 061338 Dimension Vista™ IGA Flex® reagent cartridge: The IgA method is an in vitro diagnostic test for the quantitative measurement of Immunoglobulin A in human serum and heparinized plasma on the Dimension Vista™ System. Measurements of IgA aid in the diagnosis of abnormal protein metabolism and the body's lack of ability to resist infectious agents.
Predicate devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- N Antisera To Human Immunoglobulins (Igg, Iga and Igm)K042735 · Dade Behring, Inc. · Feb 15, 2005
- Modification To N Protein Standard SLK012470 · Dade Behring, Inc. · Sep 28, 2001
- Modification To N/T Protein Control SLK012468 · Dade Behring, Inc. · Sep 4, 2001
- Dimension Vista Integrated SystemK051087 · Dade Behring, Inc. · Jul 11, 2005
Cited as a predicate
1 later 510(k) summary names this device as a predicate- Dimension Vista Protein 1 Calibrator, Control Low, Control Medium, Control HighK062055 · Dade Behring, Inc. · Aug 7, 2006
Other CFN clearances
The newest 510(k)s for the same product code; see every CFN device- N Antisera to Human Immunoglobulins (IgG, IgA, and IgM)K233663 · Siemens Healthcare Diagnostics Products GmbH · Dec 13, 2023
- Immunoglobulin G (IgG)K221114 · Beckman Coulter Laboratory Systems (Suzhou) Co., Ltd. · Aug 2, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 15, 2006
- Review panel
- Immunology
- Regulation
- 21 CFR 866.5510
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files