Unicel Dxc 600I Synchron Access Clinical System
Hexokinase, Glucose. 510(k) K060256, from Beckman Coulter, Inc. (Brea, CA). Product code CFR, class 2.
As of Nov 18, 2026, K060256 is an FDA 510(k) held by Beckman Coulter, Inc., substantially equivalent on Feb 27, 2006 after 26 days, with 24 recalls tied to it in FDA's recall database.
- Substantially equivalent: Feb 27, 2006
- Review time: 26 days
- Recalls: 24
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe UniCel® DxC 600i System combines the UniCel® DxC 600 analyzer and the Access® 2 analyzer into a single instrument presentation. Samples are loaded from a single point of entry through a Closed Tube Aliqoter (CTA) unit. The CTA functions as a sample processing manager by aliquotting and routing samples to the Access 2 and/or UniCel DxC 600 analyzer according to programming requirements.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- Synchron Lx I 725 Clinical SystemK023049 · Beckman Coulter, Inc. · Oct 4, 2002
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- Unicel Dxc 600 Synchron System Software Version 5.0 And Unicel Dxc 800 Synchron System Software Version 5.0K103842 · Beckman Coulter, Inc. · Apr 27, 2011
Recalls
Recalls FDA ties to K060256, newest first; each opens FDA's recall record| Jan 26, 2023 | Z-1257-2023An increased incidence of damage to the nut band from a new vendor (Boamax) has led to an increased volume of complaints from consignees regarding wash arm motion failures, system check failures, and/or assay… | Open, Classified |
| Nov 6, 2017 | Z-0310-2018Potential for minor skin burn if the tool contacts the reagent storage interface board (B79917) when performing a pipettor alignment. | Terminated |
| Oct 6, 2014 | Z-0176-2015Beckman Coulter is recalling the Small Form Factor Console PC (SFF PC) (B23083) for use with the DxC 600i analyzer because it may experience a "MFC Exception" error during normal operation of the analyzer system. | Terminated |
| Apr 22, 2014 | Z-2272-2016Possible leaking of No Foam solution from the No Foam Bottle Assembly on the UniCel DxC Synchron Systems. | Terminated |
| Feb 12, 2013 | Z-1035-2013Beckman Coulter is initiating a recall due to a defective newly released aluminum incubator belt pulley that may rub against the light shield, which causes the formation of debris. Debris that is caused by the incubator… | Terminated |
| Nov 1, 2012 | Z-0612-2013It has been determined that, in some cases, pulley drive components have broken parts or have become loose, mispositioned, or disconnected from their drive shafts. When these defects occur, the pulley may not turn at… | Terminated |
| Sep 3, 2012 | Z-0123-2013Beckman Coulter has confirmed that the Shuttle to Barcode Reader and Cap Piercer alignment procedure cannot be performed on certain DxC configurations with v5.0.11 software installed. If the Shuttle to Barcode Reader… | Terminated |
| Jul 6, 2012 | Z-0059-2013The recall was initiated because Beckman Coulter has confirmed that the current sample syringe pump drive assemblies installed on DxC Integrated ystem with UniCel Closted Tube Aliquotter (UCTA) serial numbers between… | Terminated |
| Nov 16, 2010 | Z-1972-2011The hose clamps in the DxC (with serial numbers less than 3412, labeled behind the lower right side instrument door) hydropneumatic system are sharp and pose a possible risk of injury. An operator could be cut by the… | Terminated |
| Oct 5, 2010 | Z-1936-2011The recall was initiated because Beckman Coulter confirmed Access waste bottles that ruptured and expelled liquid waste, exposing the operator to the system liquid waste. Over time, waste bottles can degrade, become… | Terminated |
| Aug 13, 2010 | Z-0607-2011This recall was initiated because Beckman Coulter has received reports of erroneous test results being reported as a result of assay reagent packs being transferred between systems. Erroneous results will be generated… | Terminated |
| Aug 10, 2010 | Z-1619-2011The recall was initiated because Cartridge Glucose (GLU) on UniCel DxC and Synchron LX instruments may give falsely high results for moderately hemolysed samples. The Impact: (1) Neonatal samples drawn by lancets are… | Terminated |
| Apr 15, 2010 | Z-2388-2010UniCel DxC and Synchron LX instruments produced inaccurate (low) GLUCm results. False low results could affect or delay diagnosis or treatment. | Terminated |
| Feb 25, 2010 | Z-2590-2010Beckman Coulter is initiating a recall on their UniCel DxC Clinical Systems (880i, 860i,680i and 660i Systems with serial number <2760 that have software version 4.9.01 installed and have the VME Motorola ICS board)… | Terminated |
| Jan 18, 2010 | Z-2442-2010The recall was initiated due to " A loose Aliquot Probe tube fitting in the Closed Tube Aliquotter (CTA), may result in erroneous Access immunoassay results or Synchron chemistry results". This may result in dilution of… | Terminated |
| Jan 4, 2010 | Z-0863-2010Excessive Buildup of protein, bacteria and sample tube additives in the ISE flow cell may cause erroneous NA (sodium) results. | Terminated |
| Oct 28, 2009 | Z-0856-2010This recall was initiated because of software issue was identified in System Software 4.2 and 4.2.1, which may result in the incorrect handling of a wash arm dispense plate motion failure. Instead of generating a red… | Terminated |
| Jul 23, 2009 | Z-2633-2011The recall was initiated because the Wash Concentrate Tube Assembly 142 may fail to deliver the appropriate amount of wash concentrate on some SYNCHRON DxC Systems due to an accumulation of crystals. The impact of this… | Terminated |
| May 7, 2009 | Z-2771-2011The recall was initiated after Beckman Coulter confirmed reports of inaccurate Access Intrinsic Factor Ab test results displayed on, or printed from, the UniCel Dxl portion of an integrated workstation listed above. The… | Terminated |
| Oct 9, 2008 | Z-0914-2010The recall was initiated after Beckman Coulter confirmed reports of a new premature failure of the upper aspirate peristaltic pump in the systems listed above. Premature failure of the pump may negatively affect… | Terminated |
| Sep 11, 2008 | Z-1375-2012The recall was initiated because Beckman confirmed a customer report that a timing conflict can occur while aspirating samples for the Access Total BhCG assay. | Terminated |
| Apr 3, 2008 | Z-2386-2008The field action was initiated after the firm confirmed reports of premature failure of the waste pump tubing in the Access and Access 2 Immunoassay Systems. Premature failure of the waste pump tubing may negatively… | Terminated |
| Oct 17, 2007 | Z-1183-2008Electrical grounding failure: During manufacturing, internal testing found one instrument wlth an intermittent failure of the electrical grounding. The source of the problem was traced to inadequate soldering. | Terminated |
| Apr 5, 2007 | Z-1098-2008Intermittent Failure of Stirrer Motor-Beckman Coulter has determined that incorrect Glucose results on LX20 or DxC instruments have been related to an intermittent failure of the stirrer motor. -Stirrer motors can stall… | Terminated |
Other CFR Clearances
The newest 510(k)s for the same product code; their median review was 111 days; see every CFR device- Glucose HK Gen.3; ONLINE DAT Methadone II; cobas pro integrated solutionsK253490 · Roche Diagnostics · Feb 12, 2026
- Glucose2K252357 · Abbott Ireland · Oct 24, 2025
- cobas pure integrated solutions, Glucose HK Gen.3, ISE indirect Na for Gen.2, ONLINE DAT Methadone II, Elecsys TSHK220134 · Roche Diagnostics · Sep 16, 2022
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Feb 1, 2006
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1345
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files