Carto Rmt Ep Navigation System V8
Catheter, Electrode Recording, Or Probe, Electrode Recording. 510(k) K060047, from Biosense Webster, Inc. (Diamond Bar, CA). Product code DRF, class 2.
As of Nov 21, 2026, K060047 is an FDA 510(k) held by Biosense Webster, Inc., substantially equivalent on Jun 19, 2006 after 164 days, with no recalls tied to it in FDA's recall database.
- Review time: 164 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The intended use of the CARTO™ RMT EP Navigation System v8 is catheter-based atrial and ventricular mapping. The CARTO RMT System v8 allows real-time display of cardiac maps in a number of different formats. Maps may be displayed as cardiac electrical activation maps, cardiac electrical propagation maps, cardiac electrical potential maps, impedance maps, and cardiac chamber geometry maps.
- Carto Rmt Ep Navigation System V8K091789 · Biosense Webster, Inc. · Oct 1, 2009
- Carto 3 Ep Navigation System, V1.0 and AccessoriesK090017 · Biosense Webster, Inc. · Oct 13, 2009
- Carto 3 Navigation System (Model:FG-5400-00), Carto 3 External Reference Patches (Model:D-1283-01)K072202 · Biosense Webster, Inc. · Nov 19, 2007
- Khelix Magnetic Sensor Electrophysiology Catheter (SS1-*-*-MAG)K262068 · CathRx, Ltd. · Oct 9, 2026
- Vision-MR™ Diagnostic CatheterK252794 · Imricor Medical Systems, Inc. · Jan 8, 2026
- MAGiC Sweep™ EP Mapping CatheterK250590 · Stereotaxis, Inc. · Jul 23, 2025
- VIKING™ Fixed Curve Diagnostic CatheterK250310 · Boston Scientific Corporation · Jun 27, 2025
- EP•XT™ Unidirectional Steerable Diagnostic Catheter; Dynamic Tip™ Unidirectional Steerable Diagnostic Catheter; Dynamic…K240366 · Boston Scientific Corporation · Nov 1, 2024
- Nordica PV Cryo Mapping CatheterK233900 · Synaptic Medical Corporation · Sep 6, 2024
- Cosine-10TM Diagnostic CatheterK233397 · Medtronic, Inc. · Dec 2, 2023
- Polaris X™ Unidirectional Steerable Diagnostic CatheterK233207 · Boston Scientific Corporation · Oct 27, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jan 6, 2006
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1220
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files