Arca
Skip to content
Tools
Tools

Cadd-Ms 3 Ambulatory Infusion Pump

Pump, Infusion. 510(k) K051568, from Smiths Medical MD, Inc. (St. Paul, MN). Product code FRN, class 2.

As of Nov 20, 2026, K051568 is an FDA 510(k) held by Smiths Medical MD, Inc., substantially equivalent on Nov 17, 2005 after 156 days, with 2 recalls tied to it in FDA's recall database.

  • Review time: 156 days
  • Recalls: 2
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

"The CADD-MS™ 3 Ambulatory Infusion Pump is designed for subcutaneous, intravenous, epidural and intrathecal infusion of medication."

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K051568, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Mar 7, 2008Z-1621-2008Smiths Medical discovered an issue with a motor component in specific serial numbers of the CADD-MS 3 Ambulatory Infusion Pump. This issue affects motor operation and may cause an over-delivery of medication which could…Terminated
Feb 22, 2008Z-1641-2008Smiths Medical has received reports that the device powers down without an alarm. Investigation concluded that if the battery cap is not fully tightened, the pump may power down and a brief "chirp" will sound. This may…Terminated

Other FRN clearances

The newest 510(k)s for the same product code; their median review was 242 days; see every FRN device

Record

Type
Traditional
Received
Jun 14, 2005
Review panel
General Hospital
Regulation
21 CFR 880.5725

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files