Philips Heartstart Frx Defibrillator, Model 861304

Automated External Defibrillators (Non-Wearable). 510(k) K050004, from Philips Medical Systems (Seattle, WA). Product code MKJ, class 3.

As of Nov 20, 2026, K050004 is an FDA 510(k) held by Philips Medical Systems, substantially equivalent on Feb 25, 2005 after 54 days, with 7 recalls tied to it in FDA's recall database.

  • Review time: 54 days
  • Recalls: 7
  • Cited as a predicate by: 2 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The HeartStart FRx Defibrillator should be used on a person you think is in sudden cardiac arrest. A person in sudden cardiac arrest is: If in doubt, apply the pads. A training class in CPR/AED use is recommended for anyone who may use the HeartStart FRx Defibrillator. If the person is an infant or child younger than eight years old or weighs less than 55 lbs (25 kg), use the Infant/Child Key.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

2 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K050004, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Sep 10, 2019Z-1271-2020, Z-1272-2020Affected devices contain a Printed Circuit Assembly (PCA) that was not manufactured/repaired in accordance to quality standards.Terminated
Mar 14, 2018Z-1913-2018An issue with one of the electric components (a resistor) could result in the device not delivering a shock when needed.Terminated
Jul 26, 2012Z-0642-2013Philips determined that it is important to clarify information in the Owner's Manual and keep customers informed about the maintenance of their FRx (models 861304 and 861305), OnSite (models M5066A and M5067A), or…Terminated
Apr 30, 2010Z-1915-2010Seventeen AEDs failed production line testing (Final Acceptance Test).Terminated
Nov 2, 2009Z-1193-2010Potential for failure of a capacitor during use which would prevent the AED from delivering effective defibrillation therapy when indicated.Terminated
Aug 7, 2008Z-0432-2011The affected device may not deliver appropriate defibrillation therapy.Terminated

Record

Type
Special
Received
Jan 2, 2005
Review panel
Cardiovascular
Regulation
21 CFR 870.5310

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files