Transmitter, ZS-940PA Series
Monitor, Cardiac (Incl. Cardiotachometer & Rate Alarm). 510(k) K043517, from Nihon Kohden America, Inc. (Foothill, CA). Product code DRT, class 2.
As of Nov 19, 2026, K043517 is an FDA 510(k) held by Nihon Kohden America, Inc., substantially equivalent on Feb 3, 2005 after 45 days, with no recalls tied to it in FDA's recall database.
- Review time: 45 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The device, ZS-940PA series, is intended to transmit physiological data, such as: electrocardiogram (ECG), respiration, blood oxygen saturation (SpO₂), noninvasive blood pressure (NIBP), and pulse waveform from a patient to a Nihon Kohden monitor for continuous monitoring applications. The transmitter can change channels when connected to the QI-910PK channel writer.
- Nihon Kohden Vital Sign TelemeterK153707 · Nihon Kohden Corporation · Sep 2, 2016
- Hamilton-G5K131774 · Hamilton Medical AG · Oct 9, 2013
- Intellivue CL SP02 Pod Model 865215, Intellivue CL Nbp Pod Model 865216, Intellivue Patient Monitors MP5, MP2, X2 ModelK101600 · Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · Aug 31, 2010
- The Circadia CX00 System (CX00)K262447 · Circadia Health, Inc. · Oct 15, 2026
- DistaSense(TM) (v1)K254058 · Life Detection Technologies · Sep 25, 2026
- The Circadia C300 System (C300)K261286 · Circadia Health, Inc. · May 20, 2026
- The Circadia C300 System (C300)K252676 · Circadia Health, Inc. · Feb 3, 2026
- Sleepiz One+ (Model 2.5)K253388 · Sleepiz AG · Jan 28, 2026
- Sleepiz One+ (2.5)K251364 · Sleepiz AG · Jul 29, 2025
- The Circadia C200 SystemK234003 · Circadia Technologies, Ltd. · May 30, 2024
- Vios Monitoring System(TM) Model 2050; Vios Central Station Monitor/Vios Central Server SoftwareK232354 · Murata Vios, Inc. · Mar 22, 2024
- Document
- 510(k) summary (PDF) ↗
- Type
- Abbreviated
- Received
- Dec 20, 2004
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.2300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files