Vigilance Ii Continuous Cardiac Output/Oximetry/Volumetric Monitor, Model VIG2
Computer, Diagnostic, Pre-Programmed, Single-Function. 510(k) K043103, from Edwards Lifesciences, LLC (Irvine, CA). Product code DXG, class 2.
As of Nov 17, 2026, K043103 is an FDA 510(k) held by Edwards Lifesciences, LLC, substantially equivalent on Dec 9, 2004 after 30 days, with 2 recalls tied to it in FDA's recall database.
- Substantially equivalent: Dec 9, 2004
- Review time: 30 days
- Recalls: 2
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Vigilance II CCO/SvO _{2 /CEDV Monitor is indicated for use in patients requiring monitoring of hemodynamic parameters, including cardiac output, oximetry and right ventricular ejection fraction and end diastolic volume measurements.
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- HemoSphere Advanced Monitor, HemoSphere Swan-Ganz Module, HemoSphere Oximetry CableK163381 · Edwards Lifesciences, LLC · Apr 14, 2017
Recalls
Recalls FDA ties to K043103, newest first; each opens FDA's recall record| Sep 12, 2008 | Z-0942-2012Edwards Lifesciences has made the decision to initiate a field corrective action for the Edwards Vigilance II Model: Software: versions 00.51, 00.60, 00.61, 00.62, 00.63, 00.64, 00.67, 00.69, 00.71, 00.73 due to the… | Terminated |
| May 17, 2007 | Z-0262-2008MAP offset errors: If users are "slaving" mean arterial pressure (MAP) from the bedside monitor into the Vigilance II Monitor for the purpose of the continuous calculation of systemic vascular resistance (SVR), at… | Terminated |
Other DXG Clearances
The newest 510(k)s for the same product code; their median review was 155 days; see every DXG device- Argos Infinity (Rev. 1.0)K253092 · Retia Medical Systems, Inc. · Feb 13, 2026
- VitalStream ART Connect; VitalStream-HemoK251275 · Caretaker Medical · Sep 26, 2025
- Cogent Hemodynamic Monitoring System; Cogent HMSK232048 · Icu Medical · Dec 20, 2023
- Hypotension Decision Assist Model HDA-OR2K212529 · Directed Systems, Ltd. · Nov 23, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Special
- Received
- Nov 9, 2004
- Review panel
- Cardiovascular
- Regulation
- 21 CFR 870.1435
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files