Unicel Dxc 600 And 800 Synchron Systems

Electrode, Ion Specific, Potassium. 510(k) K042291, from Beckman Coulter, Inc. (Brea, CA). Product code CEM, class 2.

As of Nov 17, 2026, K042291 is an FDA 510(k) held by Beckman Coulter, Inc., substantially equivalent on Nov 12, 2004 after 80 days, with 25 recalls tied to it in FDA's recall database.

  • Substantially equivalent: Nov 12, 2004
  • Review time: 80 days
  • Recalls: 25+
  • Cited as a predicate by: 7 devices

Indications for Use

As the 510(k) summary states them, read from FDA's summary PDF

The UniCel DxC SYNCHRON Systems are fully automated, computer-controlled clinical chemistry analyzers intended for the in vitro determination of a variety of general chemistries, therapeutic drugs, and other chemistries of clinical interest in biological fluids such as serum, plasma, urine, or cerebrospinal fluid, (sample type is chemistry dependent).

Predicate Devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a Predicate

7 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K042291, newest first; the 25 newest; each opens FDA's recall record
Jan 29, 2020Z-2136-2020Electrolyte reference reagent, used for clinical laboratory testing to determine CO2 in human serum or plasma for diagnosis and treatment of potentially serious disorders associated with changes in the body acid-base…Terminated
Dec 5, 2018Z-1078-2019When racks are front-loaded onto the sample presentation unit while samples from the automation line are being processed, a scheduling error within the software can cause mishandling of samples during the creation of an…Open, Classified
Aug 21, 2014Z-2687-2014Beckman Coulter is recalling the Sample Probe Cable because nonconforming sample probe cables may been installed on newly manufactured and/or recently serviced UniCel DxI 600 and 800 Access Immunoassay Systems, UniCel…Terminated
May 14, 2014Z-1737-2014Beckman Coulter is initiating a field action because some Ultrasonic Transducer Kits were potentially assembled with incorrect mounting screws.Terminated
Apr 22, 2014Z-2272-2016Possible leaking of No Foam solution from the No Foam Bottle Assembly on the UniCel DxC Synchron Systems.Terminated
Sep 3, 2012Z-0123-2013Beckman Coulter has confirmed that the Shuttle to Barcode Reader and Cap Piercer alignment procedure cannot be performed on certain DxC configurations with v5.0.11 software installed. If the Shuttle to Barcode Reader…Terminated
Jul 6, 2012Z-0059-2013The recall was initiated because Beckman Coulter has confirmed that the current sample syringe pump drive assemblies installed on DxC Integrated ystem with UniCel Closted Tube Aliquotter (UCTA) serial numbers between…Terminated
Oct 13, 2011Z-2259-2012The recall was initiated because Beckman Coulter has received seven reports of a software anomaly for the UniCel Dxl Immunoassay Systems. If undetected, this anomaly may cause erroneous test results.Terminated
Oct 13, 2011Z-2257-2012The recall was initiated because Beckman Coulter has received seven reports of a software anomaly for the UniCel Dxl Immunoassay Systems. If undetected, this anomaly may cause erroneous test results.Terminated
Oct 13, 2011Z-2258-2012The recall was initiated because Beckman Coulter has received seven reports of a software anomaly for the UniCel Dxl Immunoassay Systems. If undetected, this anomaly may cause erroneous test results.Terminated
Aug 1, 2011Z-0347-2013The recall was initiated because Beckman Coulter has confirmed that the UniCel Dxl and DxC Access Immunoassay Systems had field modifications to the aspirate and dispense probe assemblies.Terminated
Jan 26, 2011Z-1938-2011The recall was initiated due to Beckman Coulter receiving a report of results that were associated with incorrect patient identifications when two sample racks advanced into the sample presentation area in one push. The…Terminated
Jan 26, 2011Z-1940-2011The recall was initiated due to Beckman Coulter receiving a report of results that were associated with incorrect patient identifications when two sample racks advanced into the sample presentation area in one push. The…Terminated
Jan 26, 2011Z-1939-2011The recall was initiated due to Beckman Coulter receiving a report of results that were associated with incorrect patient identifications when two sample racks advanced into the sample presentation area in one push. The…Terminated
Nov 16, 2010Z-1972-2011The hose clamps in the DxC (with serial numbers less than 3412, labeled behind the lower right side instrument door) hydropneumatic system are sharp and pose a possible risk of injury. An operator could be cut by the…Terminated
Oct 22, 2010Z-2075-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Oct 22, 2010Z-2076-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Oct 22, 2010Z-2077-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Oct 22, 2010Z-2078-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Oct 22, 2010Z-2081-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Oct 22, 2010Z-2080-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Oct 22, 2010Z-2074-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Oct 22, 2010Z-2079-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Oct 22, 2010Z-2073-2011This recall was initiated because Beckman Coulter has confirmed that for User-Defined Chemistries (UDRs), the polychrome correction is not automatically updated when wavelengths are modified.Terminated
Aug 10, 2010Z-1619-2011The recall was initiated because Cartridge Glucose (GLU) on UniCel DxC and Synchron LX instruments may give falsely high results for moderately hemolysed samples. The Impact: (1) Neonatal samples drawn by lancets are…Terminated

Other CEM Clearances

The newest 510(k)s for the same product code; their median review was 273 days; see every CEM device

Record

Type
Traditional
Received
Aug 24, 2004
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1600

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files

Logos are each company's own site icon, matched by name through Wikidata.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.