Oec Olympus Fluoroscopic Imaging System

Interventional Fluoroscopic X-Ray System. 510(k) K041932, from Ge Oec Medical Systems, Inc. (Salt Lake City, UT). Product code OWB, class 2.

As of Nov 21, 2026, K041932 is an FDA 510(k) held by Ge Oec Medical Systems, Inc., substantially equivalent on Aug 18, 2004 after 30 days, with 7 recalls tied to it in FDA's recall database.

  • Review time: 30 days
  • Recalls: 7
  • Cited as a predicate by: 3 devices

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The OEC Olympus Mobile Fluoroscopy System is designed to provide fluoroscopic and spot-film images of the patient during diagnostic, surgical and interventional procedures. Examples of clinical application may include cholangiography, endoscopy, urologic, orthopedic, neurologic, vascular, cardiac, critical-care and emergency room procedures.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

3 later 510(k) summaries name this device as a predicate

Recalls

Recalls FDA ties to K041932, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Apr 26, 2010Z-2241-2012GE OEC recalled certain 9800 Fluoroscope & 9900 Elite Models because the Snubber Board did not conform to the IEC 60601-1 standard for clearance and creepage of voltage isolation.Terminated
Oct 10, 2008Z-2262-2012GE initiated a correction to the instructions/use due to the potential for erroneous auto injection of contrast dye.Terminated
Apr 15, 2008Z-1706-2008Use of existing four-pedal footswitch on a different machine may cause various operational errors.Terminated
Nov 19, 2007Z-2025-2012Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. GE OEC recalled imaging devices OEC 9900, OEC 9800, and OEC…Terminated
Mar 1, 2007Z-0683-2007, Z-0679-2007, Z-0676-2007During routine service, primary and/or secondary collimators may not have been properly reinstalled.Terminated

Other OWB clearances

The newest 510(k)s for the same product code; their median review was 231 days; see every OWB device

Record

Type
Traditional
Received
Jul 19, 2004
Review panel
Radiology
Regulation
21 CFR 892.1650

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files