Oec 9800 E/Cv+ Digital Mobile Imaging System
System, X-Ray, Fluoroscopic, Image-Intensified. 510(k) K024012, from Ge Oec Medical Systems (Salt Lake City, UT). Product code JAA, class 2.
As of Nov 20, 2026, K024012 is an FDA 510(k) held by Ge Oec Medical Systems, substantially equivalent on Mar 20, 2003 after 106 days, with 20 recalls tied to it in FDA's recall database.
- Review time: 106 days
- Recalls: 20
- Cited as a predicate by: 3 devices
The OEC 9800 E/CV+ Digital Mobile Imaging System is designed to provide fluoroscopic and spot-film imaging of the patient during diagnostic, surgical and interventional procedures. It includes features designed specifically for diagnostic and interventional cardiac imaging procedures, and is also intended for use in cholangiography, endoscopic, urologic, orthopedic, neurologic, vascular, critical…
- Ziehm Vision R Digital Mobile Imaging SystemK061203 · Ziehm Imaging, Inc. · Jun 19, 2006
- Oec Olympus Fluoroscopic Imaging SystemK041932 · Ge Oec Medical Systems, Inc. · Aug 18, 2004
- Oec Olympus Mobile Fluoroscopy System With Integrated NavigationK041931 · Ge Oec Medical Systems, Inc. · Aug 26, 2004
| Apr 26, 2010 | Z-2241-2012GE OEC recalled certain 9800 Fluoroscope & 9900 Elite Models because the Snubber Board did not conform to the IEC 60601-1 standard for clearance and creepage of voltage isolation. | Terminated |
| Nov 6, 2009 | Z-2240-2012GE OEC is recalling certain 9800 Image Intensified Flouroscopic x-ray systems due to customer complaint analysis showing that a replacement Hitachi 160 GB Hard Drive, when installed on certain models is susceptible of… | Terminated |
| Oct 10, 2008 | Z-2262-2012GE initiated a correction to the instructions/use due to the potential for erroneous auto injection of contrast dye. | Terminated |
| Aug 12, 2008 | Z-1885-2008, Z-1884-2008Beam limitation may be non-compliant on some X-ray units. | Terminated |
| Apr 15, 2008 | Z-1705-2008Use of existing four-pedal footswitch on a different machine may cause various operational errors. | Terminated |
| Feb 22, 2008 | Z-2038-2012Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. The vertical lift column power supply in the mainframe C-arm… | Terminated |
| Nov 19, 2007 | Z-2026-2012Please be aware that this is not a new recall. The firm has taken action; but, due to administrative issues this recall is now being classified by the Agency. GE OEC recalled imaging devices OEC 9900, OEC 9800, and OEC… | Terminated |
| Jul 6, 2007 | Z-0990-2007The Air Kerma Rate displayed value and cumulative air kerma displayed value could exceed the allowable error under certain imaging conditions. | Terminated |
| Jun 12, 2007 | Z-0849-2007X-ray systems were not configured to display Air Kerma Rate and Cumulative Air Kerma. | Terminated |
| Mar 1, 2007 | Z-0681-2007, Z-0677-2007, Z-0682-2007, Z-0680-2007During routine service, primary and/or secondary collimators may not have been properly reinstalled. | Terminated |
| Feb 9, 2007 | Z-0556-2007, Z-0559-2007, Z-0557-2007, Z-0558-2007During routine service, a cover may have been installed without the required proper lead shielding. | Terminated |
| Aug 16, 2006 | Z-1302-06X-ray systems could provide output which exceeds the 20 R/minute limit. | Terminated |
| May 31, 2006 | Z-0001-2007Weld defect- the weld between the post body and the screw was not properly formed and can fail, even when minimal force is used. | Terminated |
- Nexus DRF Digital X-ray Imaging SystemK253103 · Varex Imaging Corporation · May 29, 2026
- Insight Enhanced™ DRF (EN-1002-01)K251650 · Imaging Engineering, LLC · Sep 16, 2025
- Soteria E-ViewK242488 · Omega Medical Imaging, LLC · Jan 6, 2025
- Adora DRFi (04550010)K242948 · Nrt X-Ray A/S · Dec 23, 2024
- TRIDENT Mobile Fluoroscopy SystemK233380 · Dornier Medtech America · Jun 26, 2024
- ProxiDiagnost N90 / Precision CRF (706110, 706400)K233945 · Philips Medical Systems Dmc GmbH · Jan 11, 2024
- CombiDiagnost R90K232910 · Philips Medical Systems Dmc GmbH · Oct 19, 2023
- XIDF-AWS801, Angio Workstation (Alphenix Workstation), V9.5K232526 · Canon Medical Systems Corporation · Sep 12, 2023
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 4, 2002
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1650
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files