Griffin Spect/Ct Imaging System

System, Tomography, Computed, Emission. 510(k) K041218, from Adac Laboratories (Milpitas, CA). Product code KPS, class 2.

As of Nov 19, 2026, K041218 is an FDA 510(k) held by Adac Laboratories, substantially equivalent on May 24, 2004 after 14 days, with 11 recalls tied to it in FDA's recall database.

  • Review time: 14 days
  • Recalls: 11
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

Griffin is an imaging system combining the acquisition of single photon nuclear medicine images and images from an x-ray computed tomography system. Griffin may produce non-attenuation corrected and attenuation corrected images of the distribution of radiopharmaceuticals in the body as well as x-ray transmission images.

Predicate devices

The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K041218, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
Dec 15, 2017Z-0514-2018, Z-0513-2018During collimator exchange, the alignment of the collimator cart and detectors may cause a collimator exchange fail, and a collimator may drop to the floor beside the collimator cart. The collimator may be partially…Terminated
Mar 6, 2015Z-1779-2015, Z-1778-2015The firm was notified that the failure of the UPS accessory devices used in conjunction with Computed Tomography X-ray systems and Diagnostic Imaging systems. may result in battery acid leakage, overheating and/or…Terminated
Sep 27, 2011Z-0257-2012, Z-0258-2012, Z-0255-2012, Z-0256-2012A mechanical malfunction of the button on the hand controller on the Philips Precedence and SKYLight SPECT systems may get stuck and cause unintended motion of a detector.Terminated
Dec 28, 2010Z-1550-2011, Z-1549-2011Philips Healthcare Nuclear Medicine determined that the detector arm assembly could be compromised.Terminated
Sep 28, 2007Z-0676-2008Incorrect Measurement: The firm discovered a software defect in Cardiac and Pulmonary Viewer software application options used in the Precedence CT Sub-System. The defect causes incorrect measurements in derived images…Terminated

Other KPS clearances

The newest 510(k)s for the same product code; their median review was 88 days; see every KPS device

Record

Type
Traditional, third-party review
Received
May 10, 2004
Review panel
Radiology
Regulation
21 CFR 892.1200

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files