Peripatch Sleeve, Models G35, E35, G45, E45, G60, E60, 5C6, 5C8, 5C10
Mesh, Surgical. 510(k) K033985, from Pm Devices, Inc. (Richmond, Bc, CA). Product code FTM, class 2.
As of Nov 19, 2026, K033985 is an FDA 510(k) held by Pm Devices, Inc., substantially equivalent on Jun 4, 2004 after 164 days, with no recalls tied to it in FDA's recall database.
- Review time: 164 days
- Recalls: 0
- Cited as a predicate by: 1 device
The PeriPatch™ Sleeve is intended for use as a surgical patch mesh material to reinforce surgical staples during stapling procedures and for reinforcing suture lines for cardiovascular and general procedures. Stapling is carried out according to the stapler manufacture's instructions.
- Peripatch Sheet, Models 1.5P8, 4P4, 4P6, 6P8, 10P16, 1.5P16K031948 · Pm Devices, Inc. · Sep 16, 2003
- Glycar Pericardial PatchK963967 · Glycar, Inc. · Oct 31, 1997
- Peri-Guard, CV Peri-Guard, Ocu-Guard, Supple Peri-Guard, Peri-Strips - Sleeve, Peri-Strips-Strips, Peri-Strips Dry, VascK983162 · Bio-Vascular, Inc. · Oct 9, 1998
- Vascu-GuardK942010 · Bio-Vascular, Inc. · Jul 7, 1994
- Tissue Patch, Tissue GraftK921895 · Bio-Vascular, Inc. · Nov 4, 1992
- Peripatch Endo-SleeveK063556 · Pm Devices, Inc. · Mar 20, 2007
- EluPro Antibiotic-Eluting BioEnvelopeK262406 · Boston Scientific · Aug 12, 2026
- Endoform Reconstructive Template - PLGAK250598 · Aroa Biosurgery , Ltd. · Jun 3, 2025
- OviTex PRS (Long-Term Resorbable)K243595 · TELA Bio, Inc. · Dec 19, 2024
- CanGaroo RM Antibacterial EnvelopeK233991 · Elutia, Inc. · Jun 14, 2024
- OviTex PRSK241126 · TELA Bio, Inc. · May 22, 2024
- Peri-Guard and Supple Peri-GuardK223052 · Synovis Life Technologies, Inc. · Apr 7, 2023
- OviTex PRS (Long Term Resorbable)K214070 · Tela Bio · Mar 21, 2023
- VersaWrapK213163 · Alafair Biosciences, Inc. · Oct 29, 2021
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 23, 2003
- Review panel
- General, Plastic Surgery
- Regulation
- 21 CFR 878.3300
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files