\Resenius Access Flow Reserving Connectors, Fresenius Standalone Accces Flow Reserving Connector
Accessories, Blood Circuit, Hemodialysis. 510(k) K022536, from Fresenius Medical Care (Lexington, MA). Product code KOC, class 2.
As of Nov 17, 2026, K022536 is an FDA 510(k) held by Fresenius Medical Care, substantially equivalent on Oct 30, 2002 after 90 days, with 3 recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 30, 2002
- Review time: 90 days
- Recalls: 3
- Cited as a predicate by: 1 device
Indications for Use
As the 510(k) summary states them, read from FDA's summary PDFThe Frese, nius Access Flow Reversing Connector (AFRC) is for use during hemodialysis to reverse the blood flow to and from the arterial and venous vascular access devices during hemodialysis in order to obtain an access flow measurement. The AFRC facilitates the test procedure by eliminating the need to disconnect bloodlines during the test procedure.
Predicate Devices
The legally marketed devices this 510(k) summary says it is substantially equivalent to, read from FDA's summary PDF- ReversoK994306 · Medisystems Corp. · Mar 20, 2000
Cited as a Predicate
1 later 510(k) summary names this device as a predicate- CAREline Airless Hemodialysis Blood Tubing SetsK172238 · Fresenius Medical Care Renal Therapies Group, LLC · Dec 14, 2017
Recalls
Recalls FDA ties to K022536, newest first; each opens FDA's recall record| Dec 19, 2014 | Z-1047-2015Potential for misinterpretation of the graphic display of the Blood Volume ( BV) slope | Terminated |
| Nov 25, 2008 | Z-0859-2009Port may crack and separate resulting in potential blood exposure/blood loss for the patient | Terminated |
| Nov 25, 2008 | Z-0860-2009Port may crack and separate resulting in potential blood exposure/blood loss for the patient | Terminated |
Other KOC Clearances
The newest 510(k)s for the same product code; their median review was 267 days; see every KOC device- BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR…K242176 · Nikkiso Co., Ltd. · May 15, 2025
- BLOOD TUBING LINES FOR HEMODIALYSIS AL Series (Archloop) BLOOD TUBING LINES FOR…K242479 · Nikkiso Co., Ltd. · May 15, 2025
- Blood Tubing Lines for Hemodialysis AV06C-EK231589 · Nikkiso Co., Ltd. · Jul 28, 2023
- Blood Tubing Lines for Hemodialysis AL Series (Archloop), Blood Tubing Lines for…K230514 · Nikkiso Co., Ltd. · Jun 16, 2023
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Aug 1, 2002
- Review panel
- Gastroenterology, Urology
- Regulation
- 21 CFR 876.5820
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files