Easystat PH, PCO2, PO2, Hct, Na+, K+, Ca++ Analyzer

Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph. 510(k) K021515, from Medica Corp. (Bedford, MA). Product code CHL, class 2.

As of Nov 19, 2026, K021515 is an FDA 510(k) held by Medica Corp., substantially equivalent on Jul 16, 2002 after 67 days, with 1 recall tied to it in FDA's recall database.

  • Review time: 67 days
  • Recalls: 1
  • Cited as a predicate by: 1 device

Indications for use

As the 510(k) summary states them, read from FDA's summary PDF

The EasyStat analyzer is designed for clinical laboratory use, making direct measurements of pH (hydrogen ion activity), PCO₂ (partial pressure of carbon dioxide), PO₂ (partial pressure of oxygen), Hct (Hematocrit), Na⁺ (sodium), K⁺ (potassium), and Ca²⁺ (ionized calcium) on whole blood samples from syringes or capillary tubes.

Cited as a predicate

1 later 510(k) summary names this device as a predicate

Recalls

Recalls FDA ties to K021515, newest first; recall numbers filed together for one problem share a row, and each opens FDA's recall record
StartedRecallStatus
Dec 31, 2025Z-1370-2026A systematic positive bias of up to 20% was identified across the reportable potassium range, resulting in false elevation results of patient samples when using Medica s capillary tubes.Open

Other CHL clearances

The newest 510(k)s for the same product code; their median review was 267 days; see every CHL device

Record

Type
Traditional
Received
May 10, 2002
Review panel
Clinical Chemistry
Regulation
21 CFR 862.1120

One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files