Signa Infinity Mr System With Excite Technology
System, Nuclear Magnetic Resonance Imaging. 510(k) K013636, from GE Medical Systems (Milwaukee, WI). Product code LNH, class 2.
As of Nov 19, 2026, K013636 is an FDA 510(k) held by GE Medical Systems, substantially equivalent on Jan 24, 2002 after 80 days, with 12 recalls tied to it in FDA's recall database.
- Review time: 80 days
- Recalls: 12
- Cited as a predicate by: 1 device
The GE Signa Infinity line of products are whole body magnetic resonance scanners designed to support high resolution, high signal-to-noise ratio and short scan times. The Signa Infinity System is indicated for use as a diagnostic imaging device to produce transverse, sagittal, coronal and oblique images, spectroscopic images, and/or spectra, dynamic images of the internal structures and organs…
- 1.5T Infinity Twinspeed Mr SystemK012200 · GE Medical Systems · Aug 3, 2001
- GE Signa Asset Imaging OptionK012970 · GE Medical Systems · Sep 24, 2001
- GE Signa Excite 1.5T Mr System, GE Signa Excite 3.0T Mr SystemK041476 · Ge Medical Systems, LLC · Jun 17, 2004
| Dec 23, 2021 | Z-0605-2022The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements. | Open |
| Nov 15, 2018 | Z-0693-2019Possible incorrect software version loaded. | Terminated |
| Jun 7, 2018 | Z-0111-2019, Z-0112-2019, Z-0110-2019The latest on-site software version may not have been reinstalled at some sites after service activities were performed resulting in images possibly flipped left/right and/or there can be patient data mismatch. | Terminated |
| Aug 31, 2015 | Z-0255-2016When performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR… | Terminated |
| Jul 10, 2015 | Z-2339-2015A gradient cable in the ACGD cabinet may be missing a spacer that prevents connecting the gradient cable terminals in the wrong polarity on X gradient amplifier. This could cause images to be flipped left-right with… | Terminated |
| Mar 9, 2015 | Z-1305-2015GE Healthcare has become aware of a potential safety issue involving MRI systems due to software versions not being maintained properly at some sites. | Terminated |
| Jan 7, 2015 | Z-1035-2015At certain sites, the MRU may not be connected to the magnet. In emergency situations, a disconnected MRU could delay removal of a ferrous object from the magnet, potentially resulting in life-threatening injuries. The… | Terminated |
| Nov 21, 2011 | Z-1943-2013Screen save images are included in wrong exam due to duplicate UID creation. This may cause a safety issue due to a potential patient data mismatch.While the issue has only been observed at one customer site on the… | Terminated |
| Nov 9, 2010 | Z-1432-2011GE Healthcare has become aware of a potential issue associated with the gradient cables being inadvertently swapped while servicing the gradients on some GE Healthcare MR Systems that may impact patient safety. If the… | Terminated |
| May 11, 2009 | Z-0462-2011Signa MR Excite" 1.5T system containing 11.1_M4_0818.a software, associated with 2D Fast Spin Echo based pulse sequences (2D FSE-XL, 2D FRFSE-XL, 2D FSE-IR, 2D T2FLAIR and 2D T1FLAIR) may experience an image flip along… | Terminated |
- MAGNETOM Free.XLK262011 · Siemens Healthineers AG · Nov 5, 2026
- ECHELON SynergyK262902 · Fujifilm Corporation · Oct 9, 2026
- Vista AI ScanK260092 · Vista AI, Inc. · Oct 7, 2026
- SwiftSight-BodyCompositionK261612 · Airs Medical, Inc. · Oct 1, 2026
- APERTO Lucent MRI SystemK261283 · Fujifilm Corporation · Sep 16, 2026
- Embrace Vision Neonatal MRI SystemK261758 · Aspect Imaging, Ltd. · Sep 16, 2026
- MAGNETOM Free.Max; MAGNETOM Free.StarK260758 · Siemens Shenzhen Magnetic Resonance , Ltd. · Sep 1, 2026
- Swoop® Portable MR Imaging® SystemK262622 · Hyperfine, Inc. · Aug 19, 2026
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Nov 5, 2001
- Review panel
- Radiology
- Regulation
- 21 CFR 892.1000
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files