Horizon Outlook With Dosecom
Pump, Infusion. 510(k) K011975, from B.Braun Medical, Inc. (Carrollton, TX). Product code FRN, class 2.
As of Nov 19, 2026, K011975 is an FDA 510(k) held by B.Braun Medical, Inc., substantially equivalent on Sep 19, 2001 after 86 days, with 4 recalls tied to it in FDA's recall database.
- Review time: 86 days
- Recalls: 4
- Cited as a predicate by: 5 devices
The Horizon Outlook™ with DoseCom™ is an electrical, external volumetric infusion pump intended to provide infusions of parenteral fluids. Parenteral fluids may include all standard fluids and/or medications indicated for infusion as well as blood and blood products. Adjustable occlusion pressure settings allow arterial, epidural and intrathecal infusions.
- Perfusor Space Infusion Syringe Pump SystemK092313 · B.Braun Medical, Inc. · Nov 4, 2009
- Infusomat Space Volumetric Infusion Pump SystemK083689 · B.Braun Medical, Inc. · Jul 1, 2009
- Hospira Mednet Medication Management SuiteK042609 · Hospira, Inc. · Oct 6, 2004
- Medley System With Bar Code Module, Model 8600K041241 · Alaris Medical Systems, Inc. · Jul 6, 2004
- Medley System With Medication Management System (Mms)K030459 · Alaris Medical Systems, Inc. · Apr 4, 2003
| Nov 14, 2012 | Z-2188-2013This notice is being provided in follow up to the field correction initiated by B. Braun Medical Inc. on August 26, 2011 due to an issue in which the Outlook ES Safety Infusion System may halt infusion but the "RUN"… | Terminated |
| Sep 7, 2011 | Z-0051-2012B Braun Outlook ES Safety Infusion System "Run" Light Emitting Diodes (LEDs) pumps stop infusing and a backup alarm sounds, but the "Run" LEDs advance as if the pumps were infusing. | Terminated |
| Aug 24, 2010 | Z-0837-2011Possible pump stop with audible alarm, but no visual error indication that the pump is not delivering the medication. Under certain conditions in a network environment, Management Processor may become non-responsive,… | Terminated |
| Jul 20, 2010 | Z-0007-2012The Outlook ES Dose Guard Care Area can inadvertently be exited when the pump enters the KVO (Keep Vein Open) state. The same condition can occur when a sequence of HOLD-HOLD key strokes are performed on the pump key… | Terminated |
- RemunityPRO+ Pump for Remodulin® (treprostinil) InjectionK253703 · Deka R&D Corp · Jul 24, 2026
- FreedomEdge Infusion System; High-Flo SubQ Needle Set; Precision Flow Rate TubingK252015 · Koru Medical Systems, Inc. · Jan 28, 2026
- Spectrum IQ Infusion System with Dose IQ Safety Software (3570009)K251636 · Baxter Healthcare Corporation · Jul 28, 2025
- SIGMA Spectrum Infusion Pump with Master Drug LibraryK251640 · Baxter Healthcare Corporation · Jul 28, 2025
- MRidium 3870 MRI Infusion Pump System (3870)K242752 · Iradimed Corporation · May 28, 2025
- BD Alaris Infusion System with Guardrails Suite MXK243855 · Carefusion 303, Inc. · Apr 25, 2025
- Plum Solo™ Precision IV PumpK242114 · Icu Medical, Inc. · Apr 2, 2025
- Plum Duo™ Precision IV PumpK242115 · Icu Medical, Inc. · Apr 2, 2025
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Jun 25, 2001
- Review panel
- General Hospital
- Regulation
- 21 CFR 880.5725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files