I-Stat Portable Clinical Analyzer, Model 300
Glucose Oxidase, Glucose. 510(k) K001387, from I-Stat Corp. (East Windsor, NJ). Product code CGA, class 2.
As of Nov 17, 2026, K001387 is an FDA 510(k) held by I-Stat Corp., substantially equivalent on Oct 5, 2000 after 156 days, with 13 recalls tied to it in FDA's recall database.
- Substantially equivalent: Oct 5, 2000
- Review time: 156 days
- Recalls: 13
- Cited as a predicate by: 4 devices
Cited as a Predicate
4 later 510(k) summaries name this device as a predicate- I-Stat 1 Wireless AnalyzerK103195 · Abbott Point of Care, Inc. · Feb 8, 2011
- Epoc Bgem, Epoc Reader, Epoc Host, Epoc Care-Fill Capillary TubeK093297 · Epocal, Inc. · Jun 9, 2010
- Blood Gas, Electrolyte And Metabolite Test CardK090109 · Epocal, Inc. · Jun 24, 2009
- Epoc Blood Analysis SystemK061597 · Epocal, Inc. · Sep 27, 2006
Recalls
Recalls FDA ties to K001387, newest first; each opens FDA's recall record| Sep 8, 2011 | Z-1977-2012Some i-Stat Analyzers become uncomfortably hot to touch in the are of the battery. This is a recall extension. | Terminated |
| Sep 8, 2011 | Z-1976-2012Some i-Stat Analyzers become uncomfortably hot to touch in the are of the battery. This is a recall extension. | Terminated |
| Sep 8, 2011 | Z-1974-2012Some i-Stat Analyzers become uncomfortably hot to touch in the are of the battery. This is a recall extension. | Terminated |
| Sep 8, 2011 | Z-1973-2012Some i-Stat Analyzers become uncomfortably hot to touch in the are of the battery. This is a recall extension. | Terminated |
| Sep 8, 2011 | Z-1978-2012Some i-Stat Analyzers become uncomfortably hot to touch in the are of the battery. This is a recall extension. | Terminated |
| Sep 8, 2011 | Z-1975-2012Some i-Stat Analyzers become uncomfortably hot to touch in the are of the battery. This is a recall extension. | Terminated |
| Sep 20, 2010 | Z-0597-2011i-STAT Analyzers batteries may overheat due to a circuitry failure, resulting in the analyzer becoming uncomfortably hot in the area of the battery component. | Terminated |
| Sep 20, 2010 | Z-0598-2011i-STAT Analyzers batteries may overheat due to a circuitry failure, resulting in the analyzer becoming uncomfortably hot in the area of the battery component. | Terminated |
| Aug 20, 2010 | Z-2462-2010Reliability issues associated with broken connection pins within the downloader that mate with the pins from the analyzer. | Terminated |
| Nov 6, 2009 | Z-1133-2010Some Martel Printers used with the i-STAT 1 system have the potential of being damaged due to the use or rechargeable battery packs that do not contain a fuse. | Terminated |
| Sep 29, 2009 | Z-0865-2010Abbott Point of Care has determined that it is possible under certain circumstances that some test records could have their status update messages mis-matched with another record, resulting in the incorrect patient… | Terminated |
| Sep 9, 2009 | Z-0812-2010The storage temperature on the label on the side of the i-Stat Portable Clinical Analyzer shipping box does not match product specification. | Terminated |
| Apr 22, 2009 | Z-2328-2009It appears that the rechargeable battery pack is overheating with or without the presence of smoke. | Terminated |
Other CGA Clearances
The newest 510(k)s for the same product code; their median review was 270 days; see every CGA device- ABL90 FLEX PLUS SystemK252488 · Radiometer Medicals Aps · May 1, 2026
- YSI 2900C Biochemistry AnalyzerK210933 · Ysi, Inc. · Sep 30, 2024
- EasyStat 300K220328 · Medica Corporation · Jul 26, 2024
- i-STAT G cartridge with the i-STAT 1 SystemK223755 · Abbott Point of Care, Inc. · Sep 11, 2023
- i-STAT CG8+ cartridge with the i-STAT 1 SystemK223710 · Abbott Point of Care, Inc. · Jul 28, 2023
- GEM Premier ChemSTATK223090 · Instrumentation Laboratory CO · Jan 27, 2023
- Nova Primary Glucose Analyzer SystemK203549 · Nova Biomedical Corporation · Oct 18, 2022
- i-STAT CHEM8+ cartridge with the i-STAT 1 SystemK210958 · Abbott Point of Care, Inc. · Aug 13, 2021
Record
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- May 2, 2000
- Review panel
- Clinical Chemistry
- Regulation
- 21 CFR 862.1345
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files